PRICES include / exclude VAT
Homepage>BS Standards>13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.040 Air quality>13.040.40 Stationary source emissions>19/30395228 DC BS EN 16429. Stationary source emissions. Reference method for the determination of the concentration of gaseous hydrogen chloride (HCl) in waste gases emitted by industrial installations into the atmosphere
Sponsored link
immediate downloadReleased: 2019-12-16
19/30395228 DC BS EN 16429. Stationary source emissions. Reference method for the determination of the concentration of gaseous hydrogen chloride (HCl) in waste gases emitted by industrial installations into the atmosphere

19/30395228 DC

BS EN 16429. Stationary source emissions. Reference method for the determination of the concentration of gaseous hydrogen chloride (HCl) in waste gases emitted by industrial installations into the atmosphere

CURRENCY
LANGUAGE
English
Standard number:19/30395228 DC
Pages:42
Released:2019-12-16
Status:Draft for Comment
DESCRIPTION
This standard 19/30395228 DC BS EN 16429. Stationary source emissions. Reference method for the determination of the concentration of gaseous hydrogen chloride (HCl) in waste gases emitted by industrial installations into the atmosphere is classified in these ICS categories:
  • 13.040.40 Stationary source emissions

This document specifies the standard reference method (SRM) based on an automatic method for determination of the mass concentration of hydrogen chloride (HCl) in ducts and stacks emitting to the atmosphere. It describes the sampling and gas conditioning system.

This document specifies the characteristics to be determined and the performance criteria to be fulfilled by portable automated measuring systems (P-AMS) using the infrared measurement method. It applies for periodic monitoring and for the calibration or control of automated measuring systems (AMS) permanently installed on a stack, for regulatory or other purposes.

A number of performance characteristics with associated minimum performance criteria are specified for the measuring system (see EN 15267‑4:2017, Table 1 which gives an overview of the relevant performance characteristics and performance criteria). This document can be used as a SRM provided the expanded uncertainty of the method is less than 20 % relative at the daily Emission Limit Value (ELV), or 1 mg/m 3 for ELV below 5 mg/m 3.

This document specifies criteria for demonstration of equivalence of an alternative method (AM) to the SRM by application of EN 14793.


This product includes: