BS 7273-4:2015+A1:2021 - SET Code of practice for the operation of fire protection measures Actuation of release mechanisms for doors

BS 7273-4:2015+A1:2021 - SET

Code of practice for the operation of fire protection measures Actuation of release mechanisms for doors

Format
Availability
Price and currency
English Secure PDF
Immediate download
421.20 USD
English Hardcopy
In stock
421.20 USD
Standard number:BS 7273-4:2015+A1:2021 - SET
Pages:72
Released:2021-02-08
ISBN:978 0 539 16883 9
Status:Standard
DESCRIPTION

BS 7273-4:2015+A1:2021 - SET


This standard BS 7273-4:2015+A1:2021 - SET Code of practice for the operation of fire protection measures is classified in these ICS categories:
  • 13.220.20 Fire protection

This part of BS 7273 gives recommendations for the design, installation, commissioning and maintenance of electrical control arrangements for actuation of mechanisms that unlock, release or open doors in the event of fire. It applies to all aspects of the interface between these mechanisms and a fire detection and fire alarm system, including interfaces that incorporate acoustic coupling and radio transmission. It does not recommend whether the above mechanisms should, or should not, be used in any given premises, or in any particular circumstances.

The interface arrangements to which this part of BS 7273 applies, include any such arrangements that are designed in the event of fire to:

  1. release fire resisting doors that are normally held in the open position;
  2. unlock doors that are normally locked; or
  3. cause powered sliding doors to open.

A1This British Standard does not apply to electrically controlled systems that form part of a smoke venting system.

NOTE 1 Recommendations for the interface between these systems and a fire detection and fire alarm system are given in BS 7273 6.A1

This part of BS 7273 does not generally apply to the equipment that holds, releases, locks or unlocks the doors, or that facilitates the opening of powered sliding doors.

NOTE 2 Recommendations are given, where appropriate, for the standards to which some of this equipment needs to conform.

This part of BS 7273 does not apply to products used within the fire detection and fire alarm system that initiate the signal to actuate the door locking or release mechanisms, nor to aspects of the fire detection and fire alarm system concerned with its primary function to give warning in the event of fire.

NOTE 3 Recommendations for the design, installation, commissioning and maintenance of fire detection and fire alarm systems are given in BS 5839 1, which refers normatively to BS 7273 for the interface between a fire detection and fire alarm system and other fire protection systems and equipment.

The scope of this part of BS 7273 is shown diagrammatically in Figure 1.

Figure 1Scope of BS 7273-4