Homepage>BS Standards>13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.040 Air quality>13.040.40 Stationary source emissions>BS EN 50291-2:2019 Electrical apparatus for the detection of carbon monoxide in domestic premises Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft. Additional test methods and performance requirements
Sponsored link
immediate downloadReleased: 2019-09-11
BS EN 50291-2:2019 Electrical apparatus for the detection of carbon monoxide in domestic premises Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft. Additional test methods and performance requirements

BS EN 50291-2:2019

Electrical apparatus for the detection of carbon monoxide in domestic premises Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft. Additional test methods and performance requirements

Format
Availability
Price and currency
English Secure PDF
Immediate download
163.80 USD
English Hardcopy
In stock
163.80 USD
Standard number:BS EN 50291-2:2019
Pages:14
Released:2019-09-11
ISBN:978 0 539 00323 9
Status:Standard
DESCRIPTION

BS EN 50291-2:2019


This standard BS EN 50291-2:2019 Electrical apparatus for the detection of carbon monoxide in domestic premises is classified in these ICS categories:
  • 97.030 Domestic electrical appliances in general
  • 13.120 Domestic safety
  • 13.040.40 Stationary source emissions
  • 13.320 Alarm and warning systems

This document specifies general requirements for the construction, testing and performance of electrically operated carbon monoxide gas detection apparatus, designed for continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft.

NOTE For caravan holiday homes EN 50291-1 applies.

This document specifies apparatus designed to operate in the event of an escape of carbon monoxide and to provide a visual and audible alarms only (Type B of EN 50291-1), or to provide visual and audible alarms and an executive action in the form of an output signal that can actuate directly or indirectly a shut-off device and/or other ancillary device (Type A of EN 50291-1).

This document excludes apparatus

  • for the detection of combustible gases, other than carbon monoxide itself (see EN 50194-1),

  • for the detection of CO in industrial installations (see EN 45544-1, EN 45544-2 and EN 45544-3) or commercial premises,

  • for CO measurement for smoke and fire detection.