PRICES include / exclude VAT
Homepage>BS Standards>11 HEALTH CARE TECHNOLOGY>11.080 Sterilization and disinfection>11.080.10 Sterilizing equipment>BS EN IEC 61010-2-040:2021 Safety requirements for electrical equipment for measurement, control, and laboratory use Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
Sponsored link
immediate downloadReleased: 2021-12-07
BS EN IEC 61010-2-040:2021 Safety requirements for electrical equipment for measurement, control, and laboratory use Particular requirements for sterilizers and washer-disinfectors used to treat medical materials

BS EN IEC 61010-2-040:2021

Safety requirements for electrical equipment for measurement, control, and laboratory use Particular requirements for sterilizers and washer-disinfectors used to treat medical materials

Format
Availability
Price and currency
English Secure PDF
Immediate download
358.80 USD
English Hardcopy
In stock
358.80 USD
Standard number:BS EN IEC 61010-2-040:2021
Pages:46
Released:2021-12-07
ISBN:978 0 539 05209 1
Status:Standard
DESCRIPTION

BS EN IEC 61010-2-040:2021


This standard BS EN IEC 61010-2-040:2021 Safety requirements for electrical equipment for measurement, control, and laboratory use is classified in these ICS categories:
  • 11.080.10 Sterilizing equipment
  • 19.080 Electrical and electronic testing
  • 71.040.10 Chemical laboratories. Laboratory equipment
IEC 61010-2-040:2020 is available as IEC 61010-2-040:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 61010-2-040:2020 specifies safety requirements for electrical equipment intended for sterilization, washing, and disinfection of medical materials in the medical, veterinary, pharmaceutical and laboratory fields, when used under the environmental conditions of 1.4. Examples of such equipment include the following: - sterilizers and disinfectors using steam and/or hot water as the sterilant; - sterilizers and disinfectors using toxic gas, toxic aerosol or toxic vapour as the sterilant; - sterilizers and disinfectors using hot air or hot inert gas as the sterilant; and - washer-disinfectors. This third edition cancels and replaces the second edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - it is established on the basis of the third edition (2010) of IEC 61010?1 and its Amendment 1 (2016); - added tolerance for stability of a.c. voltage test equipment to 6.8.3.1; - the status of a Group Safety Publication has been removed (this does not change the technical requirements in the document).