Homepage>BS Standards>11 HEALTH CARE TECHNOLOGY>11.080 Sterilization and disinfection>11.080.01 Sterilization and disinfection in general>BS EN ISO 14160:2021 - TC Tracked Changes. Sterilization of health care products. Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives. Requirements for characterization, development, validation and routine control of a sterilization process for medical devices
Sponsored link
immediate downloadReleased: 2021-11-25
BS EN ISO 14160:2021 - TC Tracked Changes. Sterilization of health care products. Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives. Requirements for characterization, development, validation and routine control of a sterilization process for medical devices

BS EN ISO 14160:2021 - TC

Tracked Changes. Sterilization of health care products. Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives. Requirements for characterization, development, validation and routine control of a sterilization process for medical devices

Format
Availability
Price and currency
English Secure PDF
Immediate download
491.40 USD
English Hardcopy
In stock
491.40 USD
Standard number:BS EN ISO 14160:2021 - TC
Pages:120
Released:2021-11-25
ISBN:978 0 539 20173 4
Status:Tracked Changes
DESCRIPTION

BS EN ISO 14160:2021 - TC


This standard BS EN ISO 14160:2021 - TC Tracked Changes. Sterilization of health care products. Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives. Requirements for characterization, development, validation and routine control of a sterilization process for medical devices is classified in these ICS categories:
  • 11.080.01 Sterilization and disinfection in general

This document specifies requirements for the characterization of a liquid chemical sterilizing agent and for the development, validation, process control and monitoring of sterilization by liquid chemical sterilizing agents of single-use medical devices comprising, in whole or in part, materials of animal origin.

This document covers the control of risks arising from contamination with bacteria and fungi by application of a liquid chemical sterilization process. Risks associated with other microorganisms can be assessed using other methods (see NOTE 1).

This document is not applicable to material of human origin.

This document does not describe methods for the validation of the inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents (see NOTE 2 and NOTE 3).

This document does not describe methods for validation of the inactivation or elimination of protozoa and parasites.

The requirements for validation and routine control described in this document are only applicable to the defined sterilization process of a medical device, which is performed after the manufacturing process, and do not take account of the lethal effects of other bioburden reduction steps (see NOTE 4).

This document does not specify tests to establish the effects of any chosen sterilization process upon the fitness for use of the medical device (see NOTE 5).

This document does not cover the level of residual sterilizing agent within medical devices (see NOTE 6).

Guidance for the characterization of a liquid chemical sterilizing agent and for the development, validation, process control and monitoring of sterilization by liquid chemical sterilizing agents of single-use medical devices comprising, in whole or in part, materials of animal origin is provided in informative Annex A.

NOTE 1

The prior application of risk management principles to medical devices utilizing animal tissues, as described in ISO 22442-1 is important. ISO 18362 provides information on control of microbial risks during processing of cell-based health-care products.

NOTE 2

Liquid chemical sterilizing agents traditionally employed to sterilize animal tissues in medical devices might not be effective in inactivating the causative agents of TSE such as bovine spongiform encephalopathy (BSE), or scrapie. Satisfactory validation in accordance with this document does not necessarily demonstrate inactivation of infective agents of this type. Risk controls related to sourcing, collection and handling of animal materials are described in ISO 22442-2 .

NOTE 3

The validation of the inactivation, elimination, or elimination and inactivation of viruses and TSE agents is described in ISO 22442-3 .

NOTE 4

Manufacturing processes for medical devices containing animal tissues frequently include exposure to chemical agents which can significantly reduce the bioburden on the medical device. Following the manufacturing process, a medical device is exposed to a specified sterilization process.

NOTE 5

Such testing is a crucial part of the design and development of a medical device.

NOTE 6

ISO 10993-17 specifies a method to establish allowable limits for residues of sterilizing agents.

NOTE 7

Standards for quality management systems (see ISO 13485 ) can be used in the control of all stages of manufacture including the sterilization process.