PRICES include / exclude VAT
Homepage>CSN Standards>40 NUCLEAR ENGINEERING>4043 Closed radioactive radiators>CSN EN ISO 19238 - Radiological protection - Performance criteria for service laboratories performing biological dosimetry by cytogenetics
Sponsored link
FREE SHIPPINGReleased: 2014
CSN EN ISO 19238 - Radiological protection - Performance criteria for service laboratories performing biological dosimetry by cytogenetics

CSN EN ISO 19238

Radiological protection - Performance criteria for service laboratories performing biological dosimetry by cytogenetics

CURRENCY
LANGUAGE
English
Category:404304
Released:2014
Released:2017
Number of Standard:CSN EN ISO 19238
DESCRIPTION

EN ISO 19238


EN ISO 19238 Radiological protection - Performance criteria for service laboratories performing biological dosimetry by cytogenetics - ISO 19238:2014 provides criteria for quality assurance and quality control, evaluation of the performance, and the accreditation of biological dosimetry by cytogenetic service laboratories. ISO 19238:2014 addresses a) the confidentiality of personal information, for the customer and the service laboratory, b) the laboratory safety requirements, c) the calibration sources and calibration dose ranges useful for establishing the reference dose-effect curves that contribute to the dose estimation from chromosome aberration frequency and the minimum resolvable doses, d) the scoring procedure for unstable chromosome aberrations used for biological dosimetry, e) the criteria for converting a measured aberration frequency into an estimate of absorbed dose, f) the reporting of results, g) the quality assurance and quality control, h) informative annexes containing sample instructions for customer, sample questionnaire, sample of report, fitting of the low dose-response curve by the method of maximum likelihood and calculating the error of dose estimate, odds ratio method for cases of suspected exposure to a low dose, and sample data sheet for recording aberrations.

Original English text of CSN EN Standard.
The price of the Standard included all amendments and correcturs.
Related products
FREE SHIPPING
Released: 2012
CSN EN ISO 2919
Radiological protection - Sealed radioactive sources - General requirements and classification
LANGUAGE
English
FREE SHIPPING
Released: 2012
CSN EN ISO 29661
Reference radiation fields for radiation protection - Definitions and fundamental concepts
LANGUAGE
English
FREE SHIPPING
Released: 2014
CSN EN ISO 17099
Radiological protection - Performance criteria for laboratories using the cytokinesis block micronucleus (CBMN) assay in peripheral blood lymphocytes for biological dosimetry
LANGUAGE
English
FREE SHIPPING
Released: 2006
CSN EN ISO 20553
Radiation protection - Monitoring of workers occupationally exposed to a risk of internal contamination with radioactive material
LANGUAGE
English
FREE SHIPPING
Released: 2015
CSN EN ISO 15382
Radiological protection - Procedures for monitoring the dose to the lens of the eye, the skin and the extremities
LANGUAGE
English
FREE SHIPPING
Released: 2012
CSN EN ISO 20785-1
Dosimetry for exposures to cosmic radiation in civilian aircraft - Part 1: Conceptual basis for measurements
LANGUAGE
English
FREE SHIPPING
Released: 2011
CSN EN ISO 20785-2
Dosimetry for exposures to cosmic radiation in civilian aircraft - Part 2: Characterization of instrument response
LANGUAGE
English
FREE SHIPPING
Released: 2015
CSN EN ISO 20785-3
Dosimetry for exposures to cosmic radiation in civilian aircraft - Part 3: Measurements at aviation altitudes
LANGUAGE
English
FREE SHIPPING
Released: 2015
CSN EN ISO 16638-1
Radiological protection - Monitoring and internal dosimetry for specific materials - Part 1: Inhalation of uranium compounds
LANGUAGE
English
FREE SHIPPING
Released: 2014
CSN EN ISO 28057
Dosimetry with solid thermoluminescence detectors for photon and electron radiations in radiotherapy
LANGUAGE
English