PRICES include / exclude VAT
Homepage>BS Standards>17 METROLOGY AND MEASUREMENT. PHYSICAL PHENOMENA>17.220 Electricity. Magnetism. Electrical and magnetic measurements>17.220.20 Measurement of electrical and magnetic quantities>PD IEC/PAS 63151:2018 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices. Vector measurement-based systems (Frequency range of 30 MHz to 6 GHz)
Sponsored link
immediate downloadReleased: 2018-02-28
PD IEC/PAS 63151:2018 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices. Vector measurement-based systems (Frequency range of 30 MHz to 6 GHz)

PD IEC/PAS 63151:2018

Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices. Vector measurement-based systems (Frequency range of 30 MHz to 6 GHz)

Format
Availability
Price and currency
English Secure PDF
Immediate download
465.40 USD
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
46.54 USD
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
139.62 USD
English Hardcopy
In stock
465.40 USD
Standard number:PD IEC/PAS 63151:2018
Pages:130
Released:2018-02-28
ISBN:978 0 580 51199 8
Status:Standard
DESCRIPTION

PD IEC/PAS 63151:2018


This standard PD IEC/PAS 63151:2018 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices. Vector measurement-based systems (Frequency range of 30 MHz to 6 GHz) is classified in these ICS categories:
  • 17.240 Radiation measurements
  • 17.220.20 Measurement of electrical and magnetic quantities

This Publicly Available Specification (PAS) specifies protocols and test procedures for the reproducible measurement of the peak spatial-average specific absorption rate (psSAR) induced inside a simplified model of the head or the body by radio-frequency (RF) transmitting devices, with a defined uncertainty. It provides requirements for systems using vector measurement-based systems. Such systems determine the psSAR by 3D field reconstruction within the volume of interest by specifying the requirements for the measurement system, calibration, uncertainty assessment and validation methods. The protocols and procedures apply for a significant majority of people including children during use of hand-held and bodyworn wireless communication devices.

This PAS is applicable to any wireless communication device intended to be used at a position near the human head or body at distances up to and including 200 mm. This PAS can be employed to evaluate SAR compliance of different types of wireless communication devices used next to the ear, in front of the face, mounted on the body, combined with other RF-transmitting or non-transmitting devices or accessories (e.g. belt-clip), or embedded in garments. The overall applicable frequency range is from 30 MHz to 6 GHz.

The system validation procedures provided within this PAS cover frequencies from 600 MHz to 6 GHz.

NOTE Some specifications (e.g., validation antennas and other procedures or requirements) are not yet defined over the full frequency range within the scope of this document but will be included in a future revision.

The device categories covered include but are not limited to mobile telephones, cordless microphones, auxiliary broadcast devices and radio transmitters in personal computers, desktop, laptop devices, multi-band, multi-antenna, and push-to-talk devices.