>BSI Standards >23 FLUID SYSTEMS AND COMPONENTS FOR GENERAL USE>23.120 Ventilators. Fans. Air-conditioners>BS EN 14825:2012 Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling. Testing and rating at part load conditions and calculation of seasonal performance
Not available online - contact us!
immediate downloadReleased: 2012-04-30
BS EN 14825:2012 Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling. Testing and rating at part load conditions and calculation of seasonal performance

BS EN 14825:2012

Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling. Testing and rating at part load conditions and calculation of seasonal performance

CURRENCY
376.8 EUR
Standard number:BS EN 14825:2012
Pages:76
Released:2012-04-30
ISBN:978 0 580 64486 3
Status:Standard
DESCRIPTION

BS EN 14825:2012


This standard BS EN 14825:2012 Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling. Testing and rating at part load conditions and calculation of seasonal performance is classified in these ICS categories:
  • 91.140.30 Ventilation and air-conditioning systems
  • 23.120 Ventilators. Fans. Air-conditioners
  • 27.080 Heat pumps

This European Standard covers air conditioners, heat pumps and liquid chilling packages. It applies to factory made units defined in EN 14511-1:2011, except single duct, control cabinet and close control units.

This European Standard gives the calculation methods for the determination of reference seasonal energy efficiency SEER and SEERon and reference seasonal coefficient of performance SCOP, SCOPon and SCOPnet.

Such calculation methods may be based on calculated or measured values.

In case of measured values, this European Standard covers the test methods for determination of capacities, EER and COP values during active mode at part load conditions. It also covers test methods for electric power consumption during thermostat off mode, standby mode and crankcase heater mode.

This European Standard serves as an input for the calculation of the system energy efficiency in heating mode of specific heat pump systems in buildings, as stipulated in the standard EN 15316-4-2.