BS EN 60079-10-1:2009
This standard BS EN 60079-10-1:2009 Explosive atmospheres is classified in these ICS categories:
- 29.260.20 Electrical apparatus for explosive atmospheres
- 13.230 Explosion protection
a) mines susceptible to firedamp;
b) the processing and manufacture of explosives;
c) areas where a hazard may arise due to the presence of combustible dusts or fibres;
d) catastrophic failures which are beyond the concept of abnormality;
e) rommos used for medial purposes;
f) domestic premises.
This first edition of IEC 60079-10-1 cancels and replaces the fourth edition of IEC 60079-10, published in 2002, and constitutes a technical revision. The significant technical changes with respect to the previous edition are:
- introduction of Annex D which deals with explosion hazard from flammable mists generated by the release under pressure of high flash point liquids;