BS EN 868-8:2009 Packaging for terminally sterilized medical devices Re-usable sterilization containers for steam sterilizers conforming to EN 285. Requirements and test methods

BS EN 868-8:2009

Packaging for terminally sterilized medical devices Re-usable sterilization containers for steam sterilizers conforming to EN 285. Requirements and test methods

CURRENCY
180 EUR
Standard number:BS EN 868-8:2009
Pages:22
Released:2009-10-31
ISBN:978 0 580 59167 9
Status:Standard
DESCRIPTION

BS EN 868-8:2009


This standard BS EN 868-8:2009 Packaging for terminally sterilized medical devices is classified in these ICS categories:
  • 55.120 Cans. Tins. Tubes
  • 11.080.30 Sterilized packaging
This part of EN 868 provides test methods and values for re-usable containers used as sterile barrier systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use. These containers are intended to be used in steam sterilizers conforming to EN 285. NOTE 1 The need for a packaging material inside the container is determined by the manufactures and users. This part of EN 868 only introduces performance requirements and test methods that are specific to the products covered by this part of EN 868 but does not add nor modify the general requirements specified in EN ISO 11607-1. As such, the particular requirements in 4.2 to 4.5 can be used to demonstrate compliance with one or more but not all of the requirements of EN ISO 11607-1. NOTE 2 When it is intended to use the containers in a steam sterilizer not conforming to EN 285 the sterilization performance of the container in the specific sterilization cycle to be used is validated by the user. Other attributes of the container are also reviewed for compatibility with the sterilizer cycle e.g. operating temperature. NOTE 3 When additional materials are used inside the sterile barrier system in order to ease the organization, drying or aseptic presentation (e.g. inner wrap, container filter, indicators, packing lists, mats, instrument organizer sets, tray liners or an additional envelope around the medical device) then other requirements, including the determination of the acceptability of these materials during validation activities, may apply.