Standard number:ASTM B0801-18R23
Released:01.10.2023
Status:Active
Pages:7
Section:02.03
Keywords:aluminum alloy conductors; aluminum conductors; electrical conductors; 8000-series aluminum alloy conductors; stranded aluminum conductors;
ASTM number:ASTM B801
Supersedes:B0801-18

This specification covers aluminum alloys in the 8000 series in tempers “0” and H1X or H2X bare compact-round, compressed and conventional concentric-lay-stranded conductors made from round or shaped wires used as covered or insulated electrical conductors. These conductors shall be composed of a central core surrounded by one or more compacted, compressed or conventional layers of helically applied wires. Joints may be made in any of the wires of any stranding by electric-butt welding, cold-pressure welding, or electric-butt, cold-upset welding. The construction of the conductors shall conform to the construction requirements prescribed in this specification. Tests for the mechanical and electrical properties of wire composing the conductor shall be made before standing. Wires annealed before stranding shall meet the requirements of the prescribed specification. The tensile requirements shall be the same as those for round wires of equal nominal area.

DESCRIPTION

1.1 This specification covers aluminum alloys in the 8000 series cited in B800 in tempers “0” and H1X or H2X bare compact-round, compressed and conventional concentric-lay-stranded conductors made from round or shaped wires used as covered or insulated electrical conductors. These conductors shall be composed of a central core surrounded by one or more compacted, compressed or conventional layers of helically applied wires (Explanatory Note 1 and Note 2).

1.2 The SI values for resistivity are regarded as standard. For all other properties, the inch-pound units are regarded as standard and the SI units may be approximate.

1.3 Sealed conductors that are intended to prevent longitudinal water propagation are also permitted within the guidelines of this specification.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Related products
English Secure PDF
Immediate download
Non-printable
61.20 EUR
English Hardcopy
In stock
61.20 EUR
English Secure PDF
Immediate download
Non-printable
61.20 EUR
English Hardcopy
In stock
61.20 EUR
English Secure PDF
Immediate download
Non-printable
61.20 EUR
English Hardcopy
In stock
61.20 EUR
English Secure PDF Redline
Immediate download
Non-printable
73.10 EUR
English Secure PDF
Immediate download
Non-printable
61.20 EUR
English Hardcopy
In stock
61.20 EUR
English Secure PDF Redline
Immediate download
Non-printable
73.10 EUR
English Secure PDF
Immediate download
Non-printable
61.20 EUR
English Hardcopy
In stock
61.20 EUR
English Secure PDF
Immediate download
Non-printable
61.20 EUR
English Hardcopy
In stock
61.20 EUR
English Secure PDF Redline
Immediate download
Non-printable
73.10 EUR
English Secure PDF
Immediate download
Non-printable
61.20 EUR
English Hardcopy
In stock
61.20 EUR