BS 3905:1995 Specification for 3.8/6.6 kV, 300 A bolted flameproof cable couplers and adaptors, for use in coal mines.

BS 3905:1995

Specification for 3.8/6.6 kV, 300 A bolted flameproof cable couplers and adaptors, for use in coal mines.

Format
Availability
Price and currency
English Secure PDF
Immediate download
317.20 USD
English Hardcopy
In stock
317.20 USD
Standard number:BS 3905:1995
Pages:36
Released:1995-11-15
ISBN:0 580 22639 5
Status:Standard
DESCRIPTION

BS 3905:1995


This standard BS 3905:1995 Specification for 3.8/6.6 kV, 300 A bolted flameproof cable couplers and adaptors, for use in coal mines. is classified in these ICS categories:
  • 29.260.20 Electrical apparatus for explosive atmospheres
  • 29.120.30 Plugs, socket-outlets, couplers

This British Standard specifies requirements for 300 A bolted flameproof cable couplers and adaptors of semi-screened three-phase, or unscreened three-phase with centre pilot tube type, with a voltage rating of 3.8/6.6 kV. The couplers are designed to enable two cables to be coupled together or to enable a cable to be coupled to apparatus by use of adaptors, in both cases the electrical connections being made by separate connecting pins. Provision is also made for insulated end covers.

The use of other forms of intermediate box, with coupling arrangements as specified in this standard, are not precluded provided that all other relevant requirements of this standard are met.

The semi-screened cable couplers are primarily intended for use with three- or four-core wire armoured cables where the fourth conductor is earthed. The cable couplers incorporating a centre pilot are primarily intended for use with three-core wire armoured cables having an additional pilot core(s).

Couplers and adaptors conforming to this standard are not intended to be coupled or uncoupled when the circuit is energized. The dimensions necessary to provide for the connection of enclosures of different manufacture and some electrical and mechanical requirements are specified. This standard does not however, purport to specify a fully detailed design.

NOTE. The figures in this standard show only those essential features and dimensions for function and interchangeability. Dimensions are in millimetres.


Design and construction dimensions, cable glands and testing of semi-screened 3-phase and unscreened 3-phase with centre pilot tube.