BS EN 14319-2:2013
Thermal insulating products for building equipment and industrial installations. In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products Specification for the installed insulation products
Standard number: | BS EN 14319-2:2013 |
Pages: | 16 |
Released: | 2013-01-31 |
ISBN: | 978 0 580 53440 9 |
Status: | Standard |
BS EN 14319-2:2013: Thermal Insulating Products for Building Equipment and Industrial Installations
Discover the ultimate solution for thermal insulation in building equipment and industrial installations with the BS EN 14319-2:2013 standard. This comprehensive specification is designed to ensure the highest quality and performance of in-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products.
Overview
The BS EN 14319-2:2013 standard provides detailed specifications for the installation of thermal insulating products, specifically focusing on in-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products. These materials are renowned for their exceptional insulating properties, making them ideal for a wide range of applications in both building equipment and industrial installations.
Key Features
- Standard Number: BS EN 14319-2:2013
- Pages: 16
- Release Date: January 31, 2013
- ISBN: 978 0 580 53440 9
- Status: Standard
Benefits of Using BS EN 14319-2:2013
Implementing the BS EN 14319-2:2013 standard in your projects offers numerous benefits:
- Enhanced Thermal Performance: The specification ensures that the insulation products deliver superior thermal performance, reducing energy consumption and improving energy efficiency.
- Quality Assurance: Adhering to this standard guarantees that the insulation products meet rigorous quality criteria, providing peace of mind and reliability.
- Versatility: Suitable for a variety of applications, the standard covers both building equipment and industrial installations, offering flexibility in usage.
- Durability: The in-situ formed dispensed rigid PUR and PIR foams are known for their long-lasting durability, ensuring that the insulation remains effective over time.
Applications
The BS EN 14319-2:2013 standard is applicable to a wide range of sectors, including:
- Construction: Ideal for insulating building equipment such as HVAC systems, piping, and ductwork.
- Industrial: Suitable for use in industrial installations, including storage tanks, process vessels, and other equipment requiring thermal insulation.
- Energy Sector: Enhances energy efficiency in power plants and other energy-related facilities.
Why Choose In-Situ Formed Dispensed Rigid PUR and PIR Foams?
In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foams are chosen for their exceptional insulating properties. These materials offer:
- High Insulation Value: Both PUR and PIR foams provide excellent thermal resistance, making them highly effective at reducing heat transfer.
- Lightweight and Strong: Despite their lightweight nature, these foams are incredibly strong and durable, providing long-term insulation solutions.
- Moisture Resistance: The closed-cell structure of these foams makes them resistant to moisture, preventing water absorption and maintaining insulation integrity.
- Fire Resistance: PIR foams, in particular, offer enhanced fire resistance, adding an extra layer of safety to your installations.
Conclusion
For those seeking a reliable and efficient solution for thermal insulation in building equipment and industrial installations, the BS EN 14319-2:2013 standard is an indispensable resource. By specifying the use of in-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products, this standard ensures that your insulation needs are met with the highest quality and performance.
Embrace the benefits of enhanced thermal performance, quality assurance, and versatility by integrating the BS EN 14319-2:2013 standard into your projects. Whether in construction, industrial, or energy sectors, this standard provides the framework for achieving superior insulation results.
BS EN 14319-2:2013
This standard BS EN 14319-2:2013 Thermal insulating products for building equipment and industrial installations. In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products is classified in these ICS categories:
- 91.100.60 Thermal and sound insulating materials
This European Standard specifies requirements for in-situ formed dispensed polyurethane (PUR) and polyisocyanurate (PIR) foam products for the insulation of building equipment industrial installations, for example storage vessels, pipes and ducts used for the supply of fuels, oil, other liquids, hot and cold water, air and other gases.
Depending on the type of foam products complying with this standard, they may have service temperature ranges which lie within the limits of ± 200 °C.
This Part 2 of this European Standard is a specification for the installed insulation product.
This Part 2 of this European Standard describes, when taken together with Part 1 of EN 14319, the product characteristics that are linked to the essential requirements of the EU Construction Products Directive. It also specifies the checks and tests to be used for the declarations made by the installer of the product.
This European Standard does not specify the required levels of all properties to be achieved by a product to demonstrate fitness for purpose in a particular application. The required levels are to be found in regulations or non-conflicting standards.
This European Standard does not cover factory made rigid polyurethane (PUR) or polyisocyanurate (PIR) foam products or in-situ products intended to be used for the insulation of buildings.
The products are not intended for use for direct airborne sound insulation or acoustic absorption applications.
NOTE Foam products are either called flexible or rigid. The flexible products are used in upholstery and mattresses and are characterised by their ability to deflect, support and recover to their original thickness continually during their in-use phase. Those that are not flexible are termed rigid and do not possess these flexible characteristics. They are mostly used for thermal insulation purposes and vary widely in their compression strength values. Once the cell structure is crushed in a rigid foam, it does not recover its thickness fully. Some of these rigid foams are very low in density with very low compression strengths and are sometimes described “commercially” as “soft foams” or “semi-rigid” foams. This note has been included to clarify that all foams with such descriptions are covered by this standard’s used of the term rigid foam.