PRICES include / exclude VAT
Homepage>BS Standards>13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.280 Radiation protection>BS ISO 28218:2010 Radiation protection. Performance criteria for radiobioassay
Sponsored link
immediate downloadReleased: 2010-10-31
BS ISO 28218:2010 Radiation protection. Performance criteria for radiobioassay

BS ISO 28218:2010

Radiation protection. Performance criteria for radiobioassay

Format
Availability
Price and currency
English Secure PDF
Immediate download
377.00 USD
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
37.70 USD
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
113.10 USD
English Hardcopy
In stock
377.00 USD
Standard number:BS ISO 28218:2010
Pages:56
Released:2010-10-31
ISBN:978 0 580 57330 9
Status:Standard
DESCRIPTION

BS ISO 28218:2010


This standard BS ISO 28218:2010 Radiation protection. Performance criteria for radiobioassay is classified in these ICS categories:
  • 13.280 Radiation protection

This International Standard provides criteria for quality assurance and control, and evaluation of performance of radiobioassay service laboratories.

Criteria and guidance for in vivo radiobioassay and in vitro radiobioassay are given in separate clauses.

The following are within the scope of this International Standard:

  • the accuracy of

    • in vivo measurements of activity and quantities of selected important radionuclides in test phantoms, and

    • in vitro measurements of activity and quantities of selected important radionuclides in test samples;

  • minimal requirements for detection limit;

  • minimum testing levels and testing ranges;

  • requirements for reporting radiobioassay results by service laboratories;

  • quality assurance in service laboratories;

  • quality control in service laboratories;

  • protocol for reporting test evaluations by service laboratories to the testing laboratory;

  • default procedures when the service laboratory customer does not specify the performance criteria;

  • applications of y# for different methods (see Annexes A and B).

The following are not within the scope of this International Standard:

  • detailed radiochemical methods for separating radionuclides from biological samples;

  • detailed procedures for in vivo and in vitro radioactivity measurements;

  • biokinetic data and mathematical models for converting radiobioassay results into dose (dose assessment);

  • procedures for the preparation and distribution of test samples and phantoms by the testing laboratories.