Homepage>IEC Standards>IEC 61557-16:2023 - Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 16: Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment
download between 0-24 hoursReleased: 2023-08-25

IEC 61557-16:2023

Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 16: Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment

Sécurité électrique dans les réseaux de distribution basse tension au plus égale à 1 000 V en courant alternatif et 1 500 V en courant continu - Dispositifs de contrôle, de mesure ou de surveillance de mesures de protection - Partie 16: Équipement pour les essais de bon fonctionnement des mesures de protection des appareils électriques et/ou des appareils électromédicaux

Format
Availability
Price and currency
English/French - Bilingual PDF
Immediate download
167.40 EUR
English/French - Bilingual Hardcopy
in stock
167.40 EUR
Standard number:IEC 61557-16:2023
Released:2023-08-25
Edition:2
ICS:17.220.20
Pages (English/French - Bilingual):42
ISBN (English/French - Bilingual):9782832272510
DESCRIPTION

IEC 61557-16:2023

IEC 61557-16:2023 specifies the requirements applicable to the performance for test and measurement equipment in order to determine the effectiveness of the protective measures for electrical equipment and/or medical electrical equipment described in IEC 62353.
This International Standard is to be used in conjunction with IEC 61557-1:2019.
IEC 61557-16:2023 cancels and replaces the first edition published in 2014. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) splitting of uncertainty requirements for medical and non-medical electrical equipment in 4.2.1;
b) addition of a definition of ranges with defined uncertainty in 4.2.1 to 4.2.7;
c) addition of an optional measuring device (MD) for non-medical devices in 4.2.1;
d) addition of a limitation of the maximum intrinsic uncertainty for medical applications at leakage current in 4.2.1;
e) change of 4.2.3 from test sockets to sockets for service purposes;
f) addition of a warning in the operating instructions;
g) integration of former 6.3 into 6.2;
h) update of Table 1;
i) alignment of the structure with that of the whole IEC 61557 series.