PRICES include / exclude VAT
>UNE standards>UNE CEN/TS 17340:2020 - Stationary source emissions - Determination of mass concentration of fluorinated compounds expressed as HF - Standard reference method (Endorsed by Asociación Española de Normalización in March of 2025.)
in stockReleased: 2025-03-01
UNE CEN/TS 17340:2020 - Stationary source emissions - Determination of mass concentration of fluorinated compounds expressed as HF - Standard reference method (Endorsed by Asociación Española de Normalización in March of 2025.)

UNE CEN/TS 17340:2020

Stationary source emissions - Determination of mass concentration of fluorinated compounds expressed as HF - Standard reference method (Endorsed by Asociación Española de Normalización in March of 2025.)

Emisiones de fuentes estacionarias. Determinación de la concentración másica en compuestos fluorados, expresados como HF. Método de referencia normalizado. (Ratificada por la Asociación Española de Normalización en marzo de 2025.)

Format
Availability
Price and currency
English PDF
Immediate download
Printable
117.70 EUR
English Hardcopy
In stock
117.70 EUR
Standard number:UNE CEN/TS 17340:2020
Pages:73
Released:2025-03-01
Status:Standard
DESCRIPTION

UNE CEN/TS 17340:2020

This document specifies a manual method for the determination of the concentration of fluorinated compounds expressed in HF. Two cases are presented: first case: the measurand is the concentration of gaseous and bound to particulates fluorides; second case: the measurand is the concentration of gaseous fluorides. Three analytical techniques are proposed: ionometry, spectrophotometry and ion-exchange chromatography. This document specifies the performance characteristics to be determined and the performance criteria to be fulfilled when it is used as the Standard Reference Method (SRM) for periodic monitoring and for calibration or control of Automated Measuring Systems (AMS) permanently installed on a stack, for regulatory or other purposes. This document applies to fluoride concentrations which may vary between 0,1 mg HF/m3 and 10 mg HF/m3, at standard conditions of pressure and temperature (see NOTE). The limit of quantification of the method is estimated at 0,1 mg/m3 for a sampled volume of 0,1 m3. Interference may occur for some matrices. Known elements that may lead to interference are mentioned in Annex C. NOTE The Emission Limit Values (ELV) for HF are expressed in mg/m3, for dry gases at the standard conditions (Tstd = 273 K and Pstd = 101,3 kPa).