PRICES include / exclude VAT
>UNE standards>UNE EN 16905-5:2023 - Gas-fired endothermic engine driven heat pumps - Part 5: Calculation of seasonal performances in heating and cooling mode
in stockReleased: 2023-10-11
UNE EN 16905-5:2023 - Gas-fired endothermic engine driven heat pumps - Part 5: Calculation of seasonal performances in heating and cooling mode

UNE EN 16905-5:2023

Gas-fired endothermic engine driven heat pumps - Part 5: Calculation of seasonal performances in heating and cooling mode

Bombas de calor accionadas por motor endotérmico de gas. Parte 5: Cálculo de los rendimientos estacionales en modo de calefacción y refrigeración.

Format
Availability
Price and currency
English PDF
Immediate download
Printable
122.10 EUR
English Hardcopy
In stock
122.10 EUR
Spanish PDF
Immediate download
Printable
122.10 EUR
Spanish Hardcopy
In stock
122.10 EUR
Standard number:UNE EN 16905-5:2023
Pages:55
Released:2023-10-11
Status:Standard
Pages (Spanish):63
DESCRIPTION

UNE EN 16905-5:2023

This part of EN 16905 specifies the calculation of the seasonal performance factor for gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery, to be used outdoor. This document is used in conjunction with: a) the terms and conditions, EN 16905-1:2017 b) the safety, EN 16905-2:2021 c) the test conditions, EN 16905-3:2017 d) the test methods, EN 16905-4:2021 e) the heat pump standards, EN 14511-2:2018, EN 14511-3:2018 and EN 14825:2018. This document only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions. This document only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437:2003 + A1:2009. This document only applies to appliances having: a) gas fired endothermic engines under the control of fully automatic control systems; b) closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated; c) where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation; d) where the maximum operating pressure in the: 1) heating water circuit (if installed) does not exceed 6 bar, 2) domestic hot water circuit (if installed) does not exceed 10 bar. This document applies to GEHP appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery. This document is applicable to GEHP appliances that are intended to be type tested. Requirements for GEHP appliances that are not type tested would need to be subject to further consideration.