>UNE standards>UNE EN 50289-1-9:2017 - Communication cables - Specifications for test methods - Part 1-9: Electrical test methods - Unbalance attenuation (transverse conversion loss TCL transverse conversion transfer loss TCTL)
in stockReleased: 2017-09-06
UNE EN 50289-1-9:2017 - Communication cables - Specifications for test methods - Part 1-9: Electrical test methods - Unbalance attenuation (transverse conversion loss TCL transverse conversion transfer loss TCTL)

UNE EN 50289-1-9:2017

Communication cables - Specifications for test methods - Part 1-9: Electrical test methods - Unbalance attenuation (transverse conversion loss TCL transverse conversion transfer loss TCTL)

Cables de comunicación. Especificaciones para métodos de ensayo. Parte 1-9: Métodos de ensayo eléctricos. Desequilibrio de atenuación (pérdida de conversión transversal, pérdida de transferencia de conversión transversal).

Format
Availability
Price and currency
English PDF
Immediate download
Printable
80.30 EUR
English Hardcopy
In stock
80.30 EUR
Spanish PDF
Immediate download
Printable
80.30 EUR
Spanish Hardcopy
In stock
80.30 EUR
Standard number:UNE EN 50289-1-9:2017
Pages:24
Released:2017-09-06
Status:Standard
Pages (Spanish):27
DESCRIPTION

UNE EN 50289-1-9:2017

This draft European Standard details the test methods to determine the attenuation of converted differential-mode signals into common-mode signals, and vice versa, due to balance characteristics of cables used in analogue and digital communication systems by using the transmission measurement method. The unbalance attenuation is measured in, respectively converted to, standard operational conditions. If not otherwise specified, e.g. by product specifications, the standard operational conditions are a differential-mode which is matched with its nominal characteristic impedance (e.g. 100 ©) and a common-mode which is loaded with 50 ©. The difference between the (image) unbalance attenuation (matched conditions in the differential and common-mode) to the Betriebs- (operational) unbalance attenuation (matched conditions in differential-mode and 50 © reference load in the common-mode) is small provided the common-mode impedance Z com is in the range of 25 © to 75 ©. For cables having a nominal impedance of 100 &!, the value of the common-mode impedance Z com is about 75 &! for up to 25 pair- count unscreened pair cables, 50 &! for common screened pair cables and more than 25 pair- count unscreened pair cables, and 25 &! for individually screened pair cables. The impedance of the common-mode circuit Zcom can be measured more precisely either with a time domain reflectometer (TDR) or a network analyser. The two conductors of the pair are connected together at both ends and the impedance is measured between these conductors and the return path. This draft European Standard is bound to be read in conjunction with prEN 50289-1-1, which contains essential provisions for its application.