>UNE standards>UNE EN 50527-1:2016 - Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices - Part 1: General (Endorsed by Asociación Española de Normalización in January of 2017.)
in stockReleased: 2017-01-01
UNE EN 50527-1:2016 - Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices - Part 1: General (Endorsed by Asociación Española de Normalización in January of 2017.)

UNE EN 50527-1:2016

Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices - Part 1: General (Endorsed by Asociación Española de Normalización in January of 2017.)

Procedimiento para la evaluación de la exposición humana a campos electromagnéticos en trabajadores con dispositivos médicos implantables activos. Parte 1: Generalidades (Ratificada por la Asociación Española de Normalización en enero de 2017.)

Format
Availability
Price and currency
English PDF
Immediate download
Printable
81.40 EUR
English Hardcopy
In stock
81.40 EUR
Standard number:UNE EN 50527-1:2016
Pages:36
Released:2017-01-01
Status:Standard
DESCRIPTION

UNE EN 50527-1:2016

This European Standard provides a procedure in order to assess the risk to workers bearing one or more active implantable medical devices from exposure to electric, magnetic and electromagnetic fields at a workplace. It describes how a general risk assessment should be performed and determines whether it is necessary to carry out a detailed risk assessment. NOTE 1 This European Standard does not cover indirect effects caused by non active implants. NOTE 2 The the risk of human exposure to EMF considered is only due to malfunctioning of AIMD. Possibilities of AIMD contribution to the risk: e.g. local modification of the distribution of EMF produced by external source or production of own EMF are covered by the respective product standards for the AIMD. Based on specific workplace standards it can be determined whether preventive measures/actions must be taken to comply with the provisions of Directive 2013/35/EU. The work situation covered is considered to be under normal working conditions including normal operation, maintenance, cleaning and other situations being part of the normal work. The frequencies covered are from 0 Hz to 300 GHz. NOTE 3 The European Parliament and Council Directive 2013/35/EU will be transposed into national legislation in all the EU member countries. It is recommended that users of this standard consult the national legislation related to this transposition in order to identify the national regulations and requirements. These national regulations and requirements may have additional requirements that are not covered by this standard and take precedence. NOTE 4 Performance requirements with respect to active implantable medical devices are excluded from the scope of this standard. These are defined in the relevant particular standards for active implantable medical devices. The risk assessment decribed in this standard is only required, if an AIMD-Employee is present. AIMDs are regulated by Directive 90/385/EEC and the amendments to it. NOTE 5 Product standards EN 45502-1 and of the EN 45502-2-X series describe the product requirements for different kinds of AIMDs. Different kinds of AIMDs are e.g. pacemaker (EN 45502-2-1), implantable cardioverter defibrillators (EN 45502-2-2), cochlear implants (EN 45502-2-3), implantable neurostimulators (ISO 14708-3), implantable infusion pumps (ISO 14708-4)