UNE EN IEC 55011:2025
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement (Endorsed by Asociación Española de Normalización in August of 2025.)
Equipos industriales, científicos y médicos. Características de las perturbaciones radioeléctricas. Límites y métodos de medición. (Ratificada por la Asociación Española de Normalización en agosto de 2025.)
| Standard number: | UNE EN IEC 55011:2025 |
| Pages: | 105 |
| Released: | 2025-08-01 |
| Status: | Standard |
UNE EN IEC 55011:2025
This International Standard applies to industrial, scientific and medical electrical equipment operating in the frequency range 0 Hz to 400 GHz and to domestic and similar appliances designed to generate and/or use locally radio-frequency energy. This standard covers emission requirements related to radio-frequency (RF) disturbances in the frequency range of 9 kHz to 400 GHz. Measurements need only be performed in frequency ranges where limits are specified in Clause 6. For ISM RF applications in the meaning of the definition found in the ITU Radio Regulations (see Definition 3.1.20), this standard covers emission requirements related to radio-frequency disturbances in the frequency range of 9 kHz to 18 GHz. ISM equipment which incorporates radio transmit/receive functions (host equipment with radio functionality) is included in the scope of this document, see Annex F. However, the emission requirements in this document are not intended to be applicable to the intentional transmissions from a radio transmitter as defined by the ITU including their spurious emissions. NOTE 1 This exclusion only applies to emissions from the intentional radio transmitter. However, combination emissions, for example emissions resulting from intermodulation between the radio and the non-radio subassemblies of the ISM equipment, are not subject to this exclusion. NOTE 2 Emission requirements for induction cooking appliances are specified in CISPR 14-1 [2]1. Requirements for ISM RF lighting equipment and UV irradiators operating at frequencies within the ISM frequency bands defined by the ITU Radio Regulations are contained in this standard. Robots used for industrial, scientific and medical applications are in the scope of this document. EXAMPLE Welding robots, spraying robots, handling robots, processing robots, assembly robots, medical robots, education and experimental robots. A comprehensive list of robots in the scope of this document is given on the IEC EMC zone. NOTE 3 Flying robots, domestic helper robots, toy robots and entertainment robots are examples of robots in the scope of other CISPR standards. Equipment covered by other CISPR product and product family emission standards are excluded from the scope of this standard.