UNE EN IEC 60794-6:2020
Optical fibre cables - Part 6: Indoor-outdoor cables - Sectional specification for indoor-outdoor cables (Endorsed by Asociación Española de Normalización in January of 2021.)
Cables de fibra óptica. Parte 6: Cables interiores-exteriores. Especificación intermedia para cables interiores-exteriores (Ratificada por la Asociación Española de Normalización en enero de 2021.)
| Standard number: | UNE EN IEC 60794-6:2020 |
| Pages: | 19 |
| Released: | 2021-01-01 |
| Status: | Standard |
UNE EN IEC 60794-6:2020
This part of IEC 60794 is a sectional specification covering general features of optical fibre cables applicable to outdoor as well as indoor environments: so called indoor-outdoor cables . Indoor-Outdoor cables are deployed in outside plant environment as well as in premises and thus fulfilling outdoor as well as indoor requirements. Typical application spaces are: e.g. extension of a duct cable into a building or using this design for centralized cabling in the central office, the Premises or Local Area Network where the same cable is used for the entire length of the cabling link including both the indoor as well as the outdoor portions. Cables of which generally possess the characteristics associated with outdoor cable designs having the thermal and mechanical robustness that makes them suitable for use in the outside plant, while simultaneously being relatively flexible, compact and lightweight while exhibiting the fire performance required in indoor premises are specified in IEC 60794-6-10. Flame Retardant Outdoor cables (see IEC 60794-6-20) are used when most of the cable length is deployed as an outdoor cable with a part of its length is deployed indoors. The cable design can be derived from a typical outdoor cable design according to the product specifications described in IEC 60794-3. The specific demand related to bend radii according to the installation situation and fire performance according to the regional legislation mainly requires the appropriate selection of the jacket material in combination with other material and / or design considerations. Because of the use in buildings with tighter space restrictions, higher flexibility of the cable is often required for the installation. Often lower diameter cables are to be preferred. Indoor cables which are weatherised (see IEC 60794-6-30) are used when an indoor cable is to be used outdoors over a short distance (few meters) e.g. when the network access point, NAP, is very close to the building. The indoor-outdoor fibre optical cable design can be derived from an indoor design (see IEC 60794-2 and IEC TR 62901 for typical applications) with specific outdoor performance features added. Critical parameters are UV stability, and resistance against exposure to humidity.
