UNE EN IEC 61010-031:2024
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
Requisitos de seguridad de equipos eléctricos de medida, control y uso en laboratorio. Parte 031: Requisitos de seguridad para sondas de mano y sondas manipulables para medidas y ensayos eléctricos.
| Standard number: | UNE EN IEC 61010-031:2024 |
| Pages: | 108 |
| Released: | 2024-02-21 |
| Status: | Standard |
| Pages (Spanish): | 120 |
UNE EN IEC 61010-031:2024
1.1.1 Probe assemblies included in scope This part of IEC 61010 specifies safety requirements for hand-held and hand-manipulated probe assemblies of the types described below, and their related accessories. These probe assemblies are for non-contact or direct electrical connection between a part and electrical test and measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment. a) Type A: non-attenuating probe assemblies that are RATED for direct connection to voltages exceeding 30 V AC RMS, 42,4 V peak, or 60 V DC, but not exceeding 63 kV AC RMS or DC. They do not incorporate components which are intended to provide a voltage divider function or a signal conditioning function, but they may contain non-attenuating components such as fuses (see Figure 1.) b) Type B: attenuating or divider probe assemblies that are RATED for direct connection to voltages exceeding 30 V AC RMS or 60 DC but not exceeding 63 kV AC RMS or DC. The divider function may be carried out wholly within the probe assembly, or partly within the test or measurement equipment to be used with the probe assembly (see Figure 2.a and Figure 2.b). c) Type D: attenuating, non-attenuating or other signal conditioning probe assemblies, that are RATED for direct connection only to voltages not exceeding 30 V AC RMS, or 42,4 V peak, or 60 V DC, and are suitable for currents exceeding 8 A AC RMS or DC (see Figure 3). d) Type E: non-attenuating probe assemblies for 4-pole precise resistance measurements in electrical installation (see Figure 4). EXAMPLE: Kelvin probes. e) Type F: probe assemblies for non-contact AC voltage test and measurement. These probe assemblies are intended for use on non-insulated conductors without electrical contact (see Figure 5). NOTE Type F probe assemblies can be stand-alone probes or connected by a PROBE WIRE to an equipment. 1.1.2 Probe assemblies excluded from scope This standard does not apply to current sensors within the scope of IEC 61010-2-032:2019, but may apply to their input measuring circuit leads and accessories. 1.2 Object 1.2.1 Aspects included in scope The purpose of the requirements of this standard is to ensure that HAZARDS to the OPERATOR and the surrounding area are reduced to a tolerable level. Requirements for protection against particular types of HAZARDS are given in Clauses 6 to 12, as follows: a) electric shock or burn (see Clauses 6 and 9); b) mechanical HAZARDS (see Clauses 7 and 8); c) excessive temperature (see Clause 9); d) arc flash (see Clause 12). Additional requirements for probe assemblies which are designed to be powered from a low-voltage mains supply, or include other features not specifically addressed in this standard are in other parts of IEC 61010. NOTE Attention is drawn to the possible existence of additional requirements regarding the health and safety of labour forces. 1.2.2 Aspects excluded from scope This standard does not cover: a) reliable function, performance, or other properties of the probe assembly; b) effectiveness of transport packaging.