>UNE standards>UNE EN IEC 80601-2-49:2019 - Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment (Endorsed by Asociación Española de Normalización in November of 2019.)
in stockReleased: 2019-11-01
UNE EN IEC 80601-2-49:2019 - Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment (Endorsed by Asociación Española de Normalización in November of 2019.)

UNE EN IEC 80601-2-49:2019

Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment (Endorsed by Asociación Española de Normalización in November of 2019.)

Equipos electromédicos. Parte 2-49: Requisitos particulares para la seguridad básica y funcionamiento esencial de equipos multifunción de vigilancia de paciente. (Ratificada por la Asociación Española de Normalización en noviembre de 2019.)

Format
Availability
Price and currency
English PDF
Immediate download
Printable
92.40 EUR
English Hardcopy
In stock
92.40 EUR
Standard number:UNE EN IEC 80601-2-49:2019
Pages:51
Released:2019-11-01
Status:Standard
DESCRIPTION

UNE EN IEC 80601-2-49:2019

This particular standard applies to BASIC SAFETY and ESSENTIAL PERFORMANCE requirements of MULTIFUNCTION PATIENT MONITORS as defined in 201.3.201, hereafter referred to as ME EQUIPMENT or MEDICAL ELECTRICAL SYSTEMS. This particular standard applies to MULTIFUNCTION PATIENT MONITORS intended for use in professional healthcare facilities as well as in the EMERGENCY MEDICAL SERVICE ENVIRONMENT or the HOME HEALTHCARE ENVIRONMENT. The scope of this standard is restricted to ME EQUIPMENT or MEDICAL ELECTRICAL SYSTEMS intended for connection to a single PATIENT that has either two or more PHYSIOLOGICAL MONITORING UNITS. Note 1: For purposes of this standard, a pregnant mother and her fetus(es) are considered a single PATIENT. This standard does not specify requirements for individual PHYSIOLOGICAL MONITORING UNITS such as ECG, invasive pressure and pulse oximetry. The particular standards related to these PHYSIOLOGICAL MONITORING UNITS specify requirements from the perspective of stand-alone ME EQUIPMENT. This particular standard addresses the additional requirements related to MULTIFUNCTION PATIENT MONITORS.MULTIFUNCTION PATIENT MONITORS can be integrated into other ME EQUIPMENT or MEDICAL ELECTRICAL SYSTEM. When this is the case, other relevant standards also apply. EXAMPLE 1 MULTIFUNCTION PATIENT MONITOR incorporated into a critical care ventilator where ISO 80601-2-12 also applies. EXAMPLE 2 MULTIFUNCTION PATIENT MONITOR incorporated into a homecare ventilator for dependent PATIENTS where ISO 80601-2-72 also applies. EXAMPLE 3 MULTIFUNCTION PATIENT MONITOR incorporated into anesthetic workstation where ISO 80601-2- 13 also applies. EXAMPLE 4 MULTIFUNCTION PATIENT MONITOR incorporated into haemodialysis equipment IEC 60601-2-16 also applies. This standard does not apply to MULTIFUNCTION PATIENT MONITORS implanted in a PATIENT. The object of this particular standard is to establish BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for MULTIFUNCTION PATIENT MONITORS as defined in 201.3.201.