Homepage>BS Standards>91 CONSTRUCTION MATERIALS AND BUILDING>91.140 Installations in buildings>91.140.30 Ventilation and air-conditioning systems>24/30493239 DC BS EN 17625 Rooftop units - Testing and rating at standard rating conditions and part load conditions for calculation of seasonal performance
immediate downloadReleased: 2024-08-22
24/30493239 DC BS EN 17625 Rooftop units - Testing and rating at standard rating conditions and part load conditions for calculation of seasonal performance

24/30493239 DC

BS EN 17625 Rooftop units - Testing and rating at standard rating conditions and part load conditions for calculation of seasonal performance

Format
Availability
Price and currency
English Secure PDF
Immediate download
44.80 USD
English Hardcopy
In stock
44.80 USD
Standard number:24/30493239 DC
Pages:103
Released:2024-08-22
Status:Draft for Comment
DESCRIPTION

24/30493239 DC


This standard 24/30493239 DC BS EN 17625 Rooftop units - Testing and rating at standard rating conditions and part load conditions for calculation of seasonal performance is classified in these ICS categories:
  • 91.140.30 Ventilation and air-conditioning systems
document specifies the terms and definitions, the test conditions and the test methods of air-sourced and water-cooled roof-top units, driven by electric compressor(s), which may be equipped with a supplementary heater using electrical resistance or combustion of fossil fuel. This document covers roof-top units with 2, 3 or 4 dampers, including several features as the free-cooling, mixing air flows (on both sides) and heat recovery. This document deals with roof-top units providing space heating and/or cooling for comfort application. Process applications are not covered by this document. This document provides the part load conditions and the calculation methods taking into account roof-top units features for the determination of seasonal energy efficiency SEER and SEERon, seasonal space cooling energy efficiency ηs,c, seasonal coefficient of performance SCOP, SCOPon and SCOPnet, seasonal space heating energy efficiency ηs,h and the overall annual efficiency. Such calculation methods may be based on calculated or measured values. In case of measured values, this document covers the test methods for determination of capacities, EER and COP values during active mode at part load conditions. It also covers test methods for the determination of power input during thermostat-off mode, standby mode, off-mode and crankcase heater mode. A roof-top unit that is not using at least the thermodynamic cycle for space heating is considered as a cooling only unit. Roof-top units equipped with additional air heating and/or cooling heat exchangers will be rated without operation of these heat exchangers.