PRICES include / exclude VAT
Homepage>ASTM Standards>ASTM B0215-20 - Standard Practices for Sampling Metal Powders
Sponsored link
Released: 2020-11-10

ASTM B0215-20

Standard Practices for Sampling Metal Powders

Format
Availability
Price and currency
English PDF Redline
Immediate download
68.48 USD
PDF
Immediate download
57.78 USD
Hardcopy
In stock
57.78 USD
Language:English
Released:2020-11-10
Pages:7
Standards number:ASTM B0215-20
Standard number:B0215-20
Released:01.11.2020
Status:Active
Pages:7
Section:02.05
Keywords:chute sampler; composite sample; gross sample; increment; Keystone sampler; micro riffler; micro splitter; riffler; sampling; scoop; slot sampler; spinning riffler; splitter; test portion; test specimen; tube sampler;
DESCRIPTION

1.1 These practices cover sampling methods used to collect a small quantity of metal powder that is as representative of the entire starting material as possible, and detail the procedures that are recommended for reducing this quantity into smaller test portions on which chemical, physical, and mechanical property data may be determined.

1.2 Several sampling practices are described, depending on their applicability to the conditions of storage and transport of the sampled powders:

1.2.1 Practice 1A (Described in Section 6)—Applicable to sampling moving powders, as when being transferred from one container to another or to a process stream; or when falling from a conveyor; or in a moving process stream. This is the preferred practice for obtaining the several increments that are combined to form the gross sample.

1.2.2 Practice 1B (Described in Section 7)—Applicable to sampling powders that have already been packaged for transport, as in a bag or drum. A hollow tubular slot sampler is the recommended way to sample these packaged powders to obtain the increments (7.1.1). Alternatively, when other methods are not possible or available, a procedure specified here (7.1.2) may be used to randomly scoop samples from the powder, using a scoop of specified material and configuration.

1.2.3 Practice 2 (Described in Section 8)—Applicable to obtaining test portions from the composite sample. For larger quantities of powder, a chute splitter is generally used, while a spinning riffler is used for smaller quantities.

1.3 These practices apply to particulate materials or mixtures of particulates with particle sizes generally less than one millimetre and include mixtures containing lubricant, with or without other non-metallic additives, that are ready for compacting.

1.4 These practices do not cover the sampling of flake powders or pastes. For procedures on the sampling and testing of flake metal powders and pastes, refer to Test Methods D480.

1.5 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.