PRICES include / exclude VAT
Homepage>ASTM Standards>23>23.040>23.040.20>ASTM F1871-24 - Standard Specification for Folded/Formed Poly-(Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation
Released: 01.02.2024

ASTM F1871-24 - Standard Specification for Folded/Formed Poly-(Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation

Standard Specification for Folded/Formed Poly-(Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation

Format
Availability
Price and currency
English PDF Redline
Immediate download
80.26 USD
English PDF
Immediate download
67.41 USD
English Hardcopy
In stock
67.41 USD
Standard number:F1871-24
Released:01.02.2024
Status:Active
Pages:7
Section:08.04
Keywords:installation, underground; plastic pipe, thermoplastic; poly (vinyl chloride) (PVC) plastic pipe; rehabilitation, trenchless technology;
DESCRIPTION

1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, and a form of marking for folded/formed poly-(vinyl chloride) (PVC) pipe for existing sewer and conduit rehabilitation.

1.2 Folded pipe produced to this specification is for use in non-pressure sewer and conduit rehabilitation where the folded PVC pipe is installed into and then expanded to provide a close fit to the wall of the original conduit, forming a new structural pipe-within-a-pipe.

Note 1: For installation procedures and design calculations refer to Practice F1867.

1.3 This specification includes pipe made only from materials specified in Section 6. This specification does not include folded pipe manufactured from reprocessed, recycled, or reclaimed PVC.

1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.5 There is no similar or equivalent ISO Standard.

1.6 The following precautionary statement pertains only to the test method portion, Section 11, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.