PRICES include / exclude VAT
Homepage>BS Standards>29 ELECTRICAL ENGINEERING>29.060 Electrical wires and cables>29.060.20 Cables>BS 4553-2:1998 Specification for 600/1000 V single-phase split concentric electric cables Cables having thermosetting insulation
immediate downloadReleased: 2005-04-29
BS 4553-2:1998 Specification for 600/1000 V single-phase split concentric electric cables Cables having thermosetting insulation

BS 4553-2:1998

Specification for 600/1000 V single-phase split concentric electric cables Cables having thermosetting insulation

Format
Availability
Price and currency
English Secure PDF
Immediate download
195.00 USD
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
19.50 USD
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
58.50 USD
English Hardcopy
In stock
195.00 USD
Standard number:BS 4553-2:1998
Pages:20
Released:2005-04-29
ISBN:0 580 29575 3
Status:Standard
DESCRIPTION

BS 4553-2:1998


This standard BS 4553-2:1998 Specification for 600/1000 V single-phase split concentric electric cables is classified in these ICS categories:
  • 29.060.20 Cables

This British Standard specifies requirements for construction and gives methods of test for XLPE-insulated single-phase split concentric cables for operation on an earthed neutral system at nominal voltages up to and including 1 000 V between phases and 600 V to earth.

The cables specified in this part of BS 4553 have a central phase conductor insulated with XLPE and a concentric layer comprising bare copper wires (earth continuity conductor) and copper wires covered with extruded polymer (neutral conductor). The cables are intended for use in fixed installations in industrial areas, buildings and similar applications. They are suitable for use in situations where the combination of ambient temperature and temperature rise due to loading current results in a conductor temperature not exceeding 90 °C and for a maximum short-circuit conductor temperature of 250 °C.

NOTE 1 Limitation on the temperature of the cables may be imposed in situations where they may be touched.

NOTE 2 Due to the relatively high conductor temperature, there is a risk of drying out the surrounding soil causing an increase in thermal resistivity which in turn would lead to the cable temperature rising to a higher value than anticipated. For cable laid directly in the ground, a suitable de-rating factor should be applied or a lower maximum sustained conductor operating temperature should be assumed to take into account the possible effects of soil drying out.

NOTE 3 In installations which include cable joints and terminations, the performance of these accessories should be taken into account in deciding the maximum operating temperature of the cable.

Guidance concerning selection, installation and usage is given in Annex A, Annex B and Annex J respectively.


Construction requirements and methods of tests for cables intended for use in fixed installations in industrial areas, buildings and similar applications. For use where current loading gives conductor temperature rise not exceeding 90°C and where maximum short circuit conductor temperature is 250°C.