Homepage>BS Standards>97 DOMESTIC AND COMMERCIAL EQUIPMENT. ENTERTAINMENT. SPORTS>97.100 Domestic, commercial and industrial heating appliances>97.100.20 Gas heaters>BS 5991:2006 Specification for indirect gas fired forced convection air heaters with rated heat inputs greater than 330 kW but not exceeding 2 MW for industrial and commercial space heating. Safety and performance requirements (excluding electrical requirements) (2nd family gases)
Sponsored link
immediate downloadReleased: 2006-07-20
BS 5991:2006 Specification for indirect gas fired forced convection air heaters with rated heat inputs greater than 330 kW but not exceeding 2 MW for industrial and commercial space heating. Safety and performance requirements (excluding electrical requirements) (2nd family gases)

BS 5991:2006

Specification for indirect gas fired forced convection air heaters with rated heat inputs greater than 330 kW but not exceeding 2 MW for industrial and commercial space heating. Safety and performance requirements (excluding electrical requirements) (2nd family gases)

Format
Availability
Price and currency
English Secure PDF
Immediate download
377.00 USD
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
37.70 USD
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
113.10 USD
English Hardcopy
In stock
377.00 USD
Standard number:BS 5991:2006
Pages:56
Released:2006-07-20
ISBN:0 580 48078 X
Status:Standard
DESCRIPTION

BS 5991:2006


This standard BS 5991:2006 Specification for indirect gas fired forced convection air heaters with rated heat inputs greater than 330 kW but not exceeding 2 MW for industrial and commercial space heating. Safety and performance requirements (excluding electrical requirements) (2nd family gases) is classified in these ICS categories:
  • 97.100.20 Gas heaters

This British Standard specifies detailed requirements, including safety and performance requirements and methods of test, for indirect gas fired forced convection air heaters having heat inputs greater than 330 kW but not exceeding 2 MW, intended for industrial and commercial applications. Appliances covered by this standard are not intended for installation in domestic dwellings.

The scope of this standard includes indirect gas fired forced convection air heaters for use both with and without ducting, and intended primarily for space heating applications.

This standard also specifies the requirements for indirect gas fired forced convection air heaters designed for permanent outdoor installation.

It applies to appliances designed to operate on normal low pressure district supplies of 2nd family gas.

For appliances fitted with gas boosters and/or flue dampers, additional requirements may apply.

This standard does not apply to portable and transportable indirect gas fired forced convection air heaters.