PRICES include / exclude VAT
Homepage>BS Standards>17 METROLOGY AND MEASUREMENT. PHYSICAL PHENOMENA>17.120 Measurement of fluid flow>17.120.01 Measurement of fluid flow in general>BS 7118-2:1989 Measurement of fluid flow: assessment of uncertainty in the calibration and use of flow measurement devices Non-linear calibration relationships
immediate downloadReleased: 1989-09-29
BS 7118-2:1989 Measurement of fluid flow: assessment of uncertainty in the calibration and use of flow measurement devices Non-linear calibration relationships

BS 7118-2:1989

Measurement of fluid flow: assessment of uncertainty in the calibration and use of flow measurement devices Non-linear calibration relationships

Format
Availability
Price and currency
English Secure PDF
Immediate download
270.40 USD
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
27.04 USD
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
81.12 USD
English Hardcopy
In stock
270.40 USD
Standard number:BS 7118-2:1989
Pages:32
Released:1989-09-29
ISBN:0 580 17382 8
Status:Standard
DESCRIPTION

BS 7118-2:1989


This standard BS 7118-2:1989 Measurement of fluid flow: assessment of uncertainty in the calibration and use of flow measurement devices is classified in these ICS categories:
  • 17.120.01 Measurement of fluid flow in general

This part of ISO 7066 describes the procedures for fitting a quadratic, cubic or higher degree polynomial expression to a non-linear2) set of calibration data, using the least-squares criterion, and of assessing the uncertainty associated with the resulting calibration curve. It considers only the use of polynomials with powers which are integers.

Because it is generally not practicable to carry out this type of curve fitting and assessment of uncertainty without using a computer, it is assumed in this part of ISO 7066 that the user has access to one. In many cases it will be possible to use standard routines available on most computers; as an alternative the FORTRAN program listed in Annex C may be used.

Examples of the use of these methods are given in Annex D.

Extrapolation beyond the range of the data is not permitted.

Annex A, Annex B, Annex C, Annex D and Annex E do not form integral parts of this part of ISO 7066.


Procedures for fitting a quadratic, cubic or higher degree polynomial expression to a non-linear set of calibration data using the least squares criterion and assessing the uncertainty associated with the resulting calibration curve.