PRICES include / exclude VAT
Homepage>BS Standards>27 ENERGY AND HEAT TRANSFER ENGINEERING>27.060 Burners. Boilers>27.060.30 Boilers and heat exchangers>BS EN 1397:2021 - TC Tracked Changes. Heat exchangers. Hydronic room fan coil units. Test procedures for establishing the performance
Sponsored link
immediate downloadReleased: 2022-04-08
BS EN 1397:2021 - TC Tracked Changes. Heat exchangers. Hydronic room fan coil units. Test procedures for establishing the performance

BS EN 1397:2021 - TC

Tracked Changes. Heat exchangers. Hydronic room fan coil units. Test procedures for establishing the performance

Format
Availability
Price and currency
English Secure PDF
Immediate download
413.40 USD
English Hardcopy
In stock
413.40 USD
Standard number:BS EN 1397:2021 - TC
Pages:82
Released:2022-04-08
ISBN:978 0 539 20137 6
Status:Tracked Changes
DESCRIPTION

BS EN 1397:2021 - TC


This standard BS EN 1397:2021 - TC Tracked Changes. Heat exchangers. Hydronic room fan coil units. Test procedures for establishing the performance is classified in these ICS categories:
  • 27.060.30 Boilers and heat exchangers

This document applies to hydronic fan coil units (FCU) as factory-made single assemblies which provide the functions of cooling and/or heating but do not include the source of cooling or heating.

This document covers both air free delivery and air ducted units with a maximum external static pressure due to duct resistance of 120 Pa max.

This document applies to all types of fan speed control of a fan coil unit (variable speed, multispeed).

This document deals with the cooling and heating functions of the FCU considered as an emitter for cooling/heating of a room/space. It does not cover any ventilation function of the unit.

If the FCU can also provide fresh air, this function is not considered and the fresh air inlet closed during testing.

This document provides a method for the determination of the thermal performance of fan coil units in standard conditions, for the use with hot or chilled water or water mixtures. The test procedures given in this standard may additionally be used for determining performance at other conditions.

It also provides the method for the determination of the air flow rate supplied by the fan coil unit.

This document does not cover the rating of heating or cooling from direct expansion coils or heating from electric resistance elements.

This document does not cover acoustic performance of fan coil units which is dealt with in EN 16583 .

It is not the purpose of this document to specify the tests used for production or field testing.

NOTE

For the purpose of remaining clauses, the term “unit” is used to mean “fan coil unit” as defined in 3.1.