Using Artificial Intelligence (AI) on standards and related intellectual property is strongly prohibited. In the event of a violation, your access to the standards will be revoked.

PRICES include / exclude VAT
Main page>BSI Standards >97 DOMESTIC AND COMMERCIAL EQUIPMENT. ENTERTAINMENT. SPORTS>97.100 Domestic, commercial and industrial heating appliances>97.100.99 Heaters using other sources of energy>BS EN 16647-2:2026 Alcohol powered flueless fireplaces. Safety requirements and test methods Automatically operated decorative fireplaces for domestic use
immediate downloadReleased: 2026-09-01
BS EN 16647-2:2026 Alcohol powered flueless fireplaces. Safety requirements and test methods Automatically operated decorative fireplaces for domestic use

BS EN 16647-2:2026

Alcohol powered flueless fireplaces. Safety requirements and test methods Automatically operated decorative fireplaces for domestic use

Format
Availability
Price and currency
English Secure PDF
Immediate download
Printable - You are authorized to print 1 copy
319.34 USD
English Hardcopy
In stock
319.34 USD
Standard number:BS EN 16647-2:2026
Pages:28
Released:2026-09-01
ISBN:978 0 539 35265 8
Status:Standard
DESCRIPTION

BS EN 16647-2:2026


This standard BS EN 16647-2:2026 Alcohol powered flueless fireplaces. Safety requirements and test methods is classified in these ICS categories:
  • 97.100.99 Heaters using other sources of energy
This document applies to decorative, automatically controlled fireplaces for domestic use, producing a flame using liquid alcohol, hereafter referred to as fuel, for decoration. NOTE 1 The requirements outlined in this document can be applied even outside domestic settings. In that case additional or different rules on the use of the fireplaces can apply. This document applies to decorative fireplaces that do not require manual user interaction during normal operation. These fireplaces include electric or electronic components that control the basic operation (incl. automatic filling system). NOTE 2 These components control the safe operation and avoid hazards such as: — Fuel spillage while filling — Overfilling — Fuel explosion while igniting — Accidental ignition while refilling — Overheating — Unsuccessful extinguishing The document applies only to fireplaces for use in indoor areas. This document applies to free-standing, wall-mounted and built-in fireplaces. This document applies to fireplaces ready for use, whose burner is an integral component of the fireplace. This document does not apply to fireplaces specifically designed for heating food or keeping food warm (rechauds), as well as to fireplaces for use in boats, caravans, other. This document does not apply to fireplaces with declared heating function. This document does not apply to fireplaces, that are connected to a flue. NOTE 3 Because of the safety component of automatically operated fireplaces this scope is not limited to a specific heat output or fuel consumption. Regarding heat output limits, national legislation can apply.
BS EN 16647-2:2026 Alcohol Powered Flueless Fireplaces

BS EN 16647-2:2026 Alcohol Powered Flueless Fireplaces

Introducing the BS EN 16647-2:2026, a comprehensive standard that sets the benchmark for safety and performance in alcohol-powered flueless fireplaces. This essential document is designed for manufacturers, designers, and safety inspectors who are involved in the creation and evaluation of automatically operated decorative fireplaces for domestic use.

Overview

The BS EN 16647-2:2026 standard is a pivotal resource that outlines the safety requirements and test methods for alcohol-powered flueless fireplaces. These fireplaces are increasingly popular due to their aesthetic appeal and the convenience of not requiring a chimney or flue. This standard ensures that these fireplaces are not only beautiful but also safe and efficient for home use.

Key Features

  • Standard Number: BS EN 16647-2:2026
  • Pages: 28
  • Release Date: September 1, 2026
  • ISBN: 978 0 539 35265 8
  • Status: Standard

Why Choose Alcohol Powered Flueless Fireplaces?

Alcohol-powered flueless fireplaces offer a unique combination of style and functionality. They are perfect for modern homes where traditional fireplaces may not be feasible. These fireplaces use alcohol as a fuel source, which burns cleanly and efficiently, producing a beautiful flame without the need for a chimney. This makes them an ideal choice for urban apartments and homes where space and ventilation may be limited.

Safety First

Safety is paramount when it comes to fireplaces, and the BS EN 16647-2:2026 standard ensures that all necessary precautions are taken. It provides detailed guidelines on the construction, installation, and operation of these fireplaces to prevent accidents and ensure user safety. The standard includes rigorous test methods to evaluate the performance and safety of the fireplaces under various conditions.

Comprehensive Test Methods

The standard includes a variety of test methods to ensure that the fireplaces meet the highest safety and performance standards. These tests cover aspects such as fuel consumption, heat output, and emissions. By adhering to these test methods, manufacturers can ensure that their products are safe, efficient, and environmentally friendly.

For Manufacturers and Designers

For manufacturers and designers, the BS EN 16647-2:2026 standard is an invaluable tool. It provides clear guidelines on the design and construction of alcohol-powered flueless fireplaces, ensuring that they meet the necessary safety and performance criteria. By following this standard, manufacturers can produce fireplaces that are not only aesthetically pleasing but also safe and reliable.

For Safety Inspectors

Safety inspectors will find the BS EN 16647-2:2026 standard to be an essential resource. It provides a comprehensive framework for evaluating the safety and performance of alcohol-powered flueless fireplaces. By using this standard, inspectors can ensure that these fireplaces are installed and operated safely, protecting consumers and enhancing public safety.

Conclusion

The BS EN 16647-2:2026 standard is a must-have for anyone involved in the design, manufacture, or inspection of alcohol-powered flueless fireplaces. It provides a thorough and detailed guide to ensuring that these fireplaces are safe, efficient, and environmentally friendly. With its comprehensive safety requirements and test methods, this standard is an essential resource for ensuring the highest quality and safety in decorative fireplaces for domestic use.

Embrace the future of home heating with confidence, knowing that your alcohol-powered flueless fireplace meets the rigorous standards set by BS EN 16647-2:2026.