Homepage>BS Standards>29 ELECTRICAL ENGINEERING>29.260 Electrical equipment for working in special conditions>29.260.20 Electrical apparatus for explosive atmospheres>BS EN 60079-35-1:2011 Household and similar electrical appliances - Safety - Part 2-82: Particular requirements for amusement machines and personal service machines
Sponsored link
immediate downloadReleased: 2012-03-31
BS EN 60079-35-1:2011 Household and similar electrical appliances - Safety - Part 2-82: Particular requirements for amusement machines and personal service machines

BS EN 60079-35-1:2011

Household and similar electrical appliances - Safety - Part 2-82: Particular requirements for amusement machines and personal service machines

Format
Availability
Price and currency
English Secure PDF
Immediate download
270.40 USD
English Hardcopy
In stock
270.40 USD
Standard number:BS EN 60079-35-1:2011
Pages:26
Released:2012-03-31
ISBN:978 0 580 76787 6
Status:Corrigendum
DESCRIPTION

BS EN 60079-35-1:2011


This standard BS EN 60079-35-1:2011 Household and similar electrical appliances - Safety is classified in these ICS categories:
  • 97.180 Miscellaneous domestic and commercial equipment
  • 97.200.40 Playgrounds
  • 29.260.20 Electrical apparatus for explosive atmospheres

This part of IEC 60079-35 specifies requirements for the construction, testing and marking of caplights, including caplights with a point of connection for other equipment, for use in mines susceptible to firedamp (Group I – electrical equipment for explosive gas atmospheres as defined in IEC 60079-0). It deals only with the risk of the caplight becoming a source of ignition.

The requirements for performance are in IEC 60079-35-2.1

This standard supplements and modifies the general requirements of IEC 60079-0 except as indicated in Table 1. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirements of this standard take precedence.

Compliance with this standard will provide an EPL of Mb (see 4.1 of this standard). If an EPL of Ma is required, the caplight will need to conform to the requirements of 4.2 of this standard, which in turn refers to IEC 60079-11.

It is expected that from time to time, caplights conforming to this standard (EPL Mb) will operate in atmospheres where the firedamp exceeds statutory levels that require the withdrawal of people from the high firedamp atmosphere to a non-hazardous area.

In designing equipment for operation in conditions other than those given above, this standard may be used as guidance; however, additional testing may be required.

Where a caplight is assessed as intrinsically safe equipment, Ex ia, conforming to IEC 60079-11 only the clauses/subclauses listed in 4.2 require application.

Table 1 – Application or exclusion of specific clauses of IEC 60079-0

Clause of IEC 60079-0 IEC 60079-0 clause application
Ed. 5.0a (2007) Ed. 6.0a (2011) Clause/subclause title (normative)
1 1 Scope Applies
2 2 Normative references Applies
3 3 Terms and definitions Applies
4 4 Equipment grouping Applies
5 5 Temperatures Applies
6.1 6.1 Requirements for all equipment – General Applies
6.2 6.2 Requirements for all equipment – Mechanical strength of equipment Applies
6.3 6.3 Requirements for all equipment – Opening times Excluded
6.4 6.4 Requirements for all equipment – Circulating currents Excluded
6.5 6.5 Requirements for all equipment – Gasket retention Applies
6.6 6.6 Requirements for all equipment – Electromagnetic and ultrasonic energy radiating equipment Applies
7 7 Non-metallic enclosures and non-metallic parts of enclosures Applies
8 8 Metallic enclosures and metallic parts of enclosures Applies
9 9 Fasteners Applies
10 10 Interlocking devices Applies
11 11 Bushings Excluded
12 12 Materials used for cementing Applies
13 13 Ex components Applies
14 14 Connection facilities and terminal compartments Applies
15 15 Connection facilities for earthing or bonding conductors Excluded
16 16 Entries into enclosures Applies
17 17 Supplementary requirements for rotating electrical machines Excluded
18 18 Supplementary requirements for switchgear Excluded
19 19 Supplementary requirements for fuses Excluded
20 20 Supplementary requirements for plugs and socket outlets and connectors Applies
21 21 Supplementary requirements for luminaires Excluded
22 22 Supplementary requirements for caplights and handlights Applies
23 23 Equipment incorporating cells and batteries Modified
24 24 Documentation Applies
25 25 Compliance of prototype or sample with documents Applies
26.1 26.1 Type tests – General Applies
26.2 26.2 Type tests – Test configuration Applies
26.3 26.3 Type tests – Tests in explosive test mixtures Applies
26.4 26.4 Type tests – Tests of enclosures Modified
26.5.1 26.5.1 Thermal tests – Temperature measurement Applies
26.5.2 26.5.2 Thermal tests – Thermal shock test Applies
26.5.3 26.5.3 Thermal tests – Small component ignition test Applies
26.6 26.6 Torque tests for bushings Excluded
26.7 26.7 Non-metallic enclosures or non-metallic parts of enclosures Applies
26.8 26.8 Thermal endurance to heat Applies
26.9 26.9 Thermal endurance to cold Applies
26.10 26.10 Resistance to light Excluded
26.11 26.11 Resistance to chemical agents for Group I electrical equipment Applies
26.12 26.12 Earth continuity Excluded
26.13 26.13 Surface resistance of parts of enclosures of non-metallic materials Applies
26.14 NR Charging tests Applies
26.15 26.14 Measurement of capacitance Applies
NR 26.15 Verification of ratings of ventilating fans Excluded
NR 26.16 Alternative qualification of elastomeric sealing O-rings Applies
27 27 Routine tests Applies
28 28 Manufacturer's responsibility Applies
29 29 Marking Modified
30 30 Instructions Applies

Applies – This requirement of IEC 60079-0 is applied without change.

Excluded – This requirement of IEC 60079-0 does not apply.

Modified – This requirement of IEC 60079-0 is modified as detailed in this standard.

NR – No requirements.

a The clause number in this table is shown for information only. The applicable requirements of IEC 60079-0 are identified by the clause title which is normative. This table was written against the specific requirements of the sixth edition of IEC 60079-0:2011. The clause numbers for the previous edition are shown for information only. This is to enable the General requirements of the fifth edition of IEC 60079-0:2007 to be used where necessary with this part of IEC 60079. Where there were no requirements (indicated by NR) or there is a conflict between requirements, the later edition requirements take precedence.