BS EN 60601-2-47:2015 - TC Tracked Changes. Medical electrical equipment Particular requirements for the basic safety and essential performance of ambulatory electrocardiographic systems

BS EN 60601-2-47:2015 - TC

Tracked Changes. Medical electrical equipment Particular requirements for the basic safety and essential performance of ambulatory electrocardiographic systems

Format
Availability
Price and currency
English Secure PDF
Immediate download
533.00 USD
English Hardcopy
In stock
533.00 USD
Standard number:BS EN 60601-2-47:2015 - TC
Released:2020-02-25
ISBN:978-0-539-08718-5
Status:Tracked Changes
DESCRIPTION

BS EN 60601-2-47:2015 - TC


This standard BS EN 60601-2-47:2015 - TC Tracked Changes. Medical electrical equipment is classified in these ICS categories:
  • 11.040.55 Diagnostic equipment
IEC 60601-2-47:2012 concerns the basic safety and essential performance of AMBULATORY ELECTROCARDIOGRAPHIC SYSTEMS. It amends and supplements the general standard IEC 60601-1 (third edition 2005). The requirements of this particular standard take priority over those of the general standard. Within the scope of this standard are systems of the following types:
a) systems that provide continuous recording and continuous analysis of the ECG allowing full re-analysis giving essentially similar results.
b) systems that provide continuous analysis and only partial or limited recording not allowing a full re-analysis of the ECG.
The safety aspects of this standard apply to all types of systems falling in one of the above- mentioned categories. If the AMBULATORY ELECTROCARDIOGRAPHIC SYSTEM offers automatic ECG analysis, minimal performance requirements for measurement and analysis functions apply. MEDICAL ELECTRICAL EQUIPMENT covered by IEC 60601-2-25 and IEC 60601-2-27 are excluded from the scope of this standard. This standard does not apply to systems that do not continuously record and analyse the ECG (for example, 'intermittent event recorders'). This second edition cancels and replaces the first edition published in 2001. It constitutes a technical revision. This edition was revised to align structurally with the 2005 edition of IEC 60601-1.