PRICES include / exclude VAT
Homepage>BS Standards>11 HEALTH CARE TECHNOLOGY>11.040 Medical equipment>11.040.55 Diagnostic equipment>BS EN 61266:1995 Ultrasonics. Hand-held probe Doppler foetal heartbeat detectors. Performance requirements and methods of measurement and reporting
immediate downloadReleased: 1995-10-15
BS EN 61266:1995 Ultrasonics. Hand-held probe Doppler foetal heartbeat detectors. Performance requirements and methods of measurement and reporting

BS EN 61266:1995

Ultrasonics. Hand-held probe Doppler foetal heartbeat detectors. Performance requirements and methods of measurement and reporting

Format
Availability
Price and currency
English Secure PDF
Immediate download
270.40 USD
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
27.04 USD
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
81.12 USD
English Hardcopy
In stock
270.40 USD
Standard number:BS EN 61266:1995
Pages:28
Released:1995-10-15
ISBN:0 580 24579 9
Status:Standard
DESCRIPTION

BS EN 61266:1995


This standard BS EN 61266:1995 Ultrasonics. Hand-held probe Doppler foetal heartbeat detectors. Performance requirements and methods of measurement and reporting is classified in these ICS categories:
  • 11.040.55 Diagnostic equipment

This International Standard IEC 1266 establishes:

  • methods of measurement of performance of a complete ultrasonic hand-held Doppler foetal heartbeat detector (hereinafter referred to as “equipment”);

  • requirements for the performance of equipment;

  • requirements for the reporting of the performance of existing equipment;

  • requirements for the declaration by manufacturers in accompanying literature of aspects of the performance of equipment.

This International Standard is applicable to ultrasonic Doppler foetal heartbeat detectors which generate a single ultrasound beam and consist of a hand-held probe which is applied to the maternal abdomen to obtain information on foetal heart activity by means of the Doppler method using continuous wave (c.w.) or quasi-continuous wave ultrasound. This standard, however, currently does not cover the continuous monitoring devices which generate more than one ultrasound beam and are usually of the type utilising a similar principle of operation but using a flat probe strapped to the patient.

This International Standard is not an equipment design standard.


Applies to detectors which generate a single continuous wave or quasi-continuous wave ultrasonic beam. It does not cover continuous monitoring devices which generate more than one ultrasound beam and use a flat standard probe strapped to a patient. This standard is not an equipment design standard.