BS EN 61472:2013 Live working. Minimum approach distances for a.c systems in the voltage range 72,5 kV to 800 kV. A method of calculation

BS EN 61472:2013

Live working. Minimum approach distances for a.c systems in the voltage range 72,5 kV to 800 kV. A method of calculation

Format
Availability
Price and currency
English Secure PDF
Immediate download
358.80 USD
English Hardcopy
In stock
358.80 USD
Standard number:BS EN 61472:2013
Pages:48
Released:2016-03-31
ISBN:978 0 580 92887 1
Status:Corrigendum
DESCRIPTION

BS EN 61472:2013


This standard BS EN 61472:2013 Live working. Minimum approach distances for a.c systems in the voltage range 72,5 kV to 800 kV. A method of calculation is classified in these ICS categories:
  • 29.240.20 Power transmission and distribution lines
  • 13.260 Protection against electric shock. Live working
  • 29.260.99 Other electrical equipment for working in special conditions

This International Standard describes a method for calculating the minimum approach distances for live working, at maximum voltages between 72,5 kV and 800 kV. This standard addresses system overvoltages and the working air distances or tool insulation between parts and/or workers at different electric potentials.

The required withstand voltage and minimum approach distances calculated by the method described in this standard are evaluated taking into consideration the following:

  • workers are trained for, and skilled in, working in the live working zone;

  • the anticipated overvoltages do not exceed the value selected for the determination of the required minimum approach distance;

  • transient overvoltages are the determining overvoltages;

  • tool insulation has no continuous film of moisture or measurable contamination present on the surface;

  • no lightning is seen or heard within 10 km of the work site;

  • allowance is made for the effect of conducting components of tools;

  • the effect of altitude, insulators in the gap, etc, on the electric strength is taken into consideration.

For conditions other than the above, the evaluation of the minimum approach distances may require specific data, derived by other calculation or obtained from additional laboratory investigations on the actual situation.