PRICES include / exclude VAT
Homepage>BS Standards>91 CONSTRUCTION MATERIALS AND BUILDING>91.120 Protection of and in buildings>91.120.20 Acoustics in building. Sound insulation>BS EN ISO 15186-3:2010 Acoustics. Measurement of sound insulation in buildings and of building elements using sound intensity Laboratory measurements at low frequencies
immediate downloadReleased: 2010-11-30
BS EN ISO 15186-3:2010 Acoustics. Measurement of sound insulation in buildings and of building elements using sound intensity Laboratory measurements at low frequencies

BS EN ISO 15186-3:2010

Acoustics. Measurement of sound insulation in buildings and of building elements using sound intensity Laboratory measurements at low frequencies

Format
Availability
Price and currency
English Secure PDF
Immediate download
195.00 USD
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
19.50 USD
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
58.50 USD
English Hardcopy
In stock
195.00 USD
Standard number:BS EN ISO 15186-3:2010
Pages:22
Released:2010-11-30
ISBN:978 0 580 71779 6
Status:Corrigendum
DESCRIPTION

BS EN ISO 15186-3:2010


This standard BS EN ISO 15186-3:2010 Acoustics. Measurement of sound insulation in buildings and of building elements using sound intensity is classified in these ICS categories:
  • 91.120.20 Acoustics in building. Sound insulation

1.1 General

This part of ISO 15186 specifies a sound intensity method to determine the sound reduction index and the element-normalized level difference of building elements at low frequencies. This method has significantly better reproducibility in a typical test facility than those of ISO 140-3, ISO 140-10 and ISO 15186-1. The results are more independent of the room dimensions of the laboratory and closer to values that would be measured between rooms of volume greater than 300 m3. This part of ISO 15186 is applicable in the frequency range 50 Hz to 160 Hz but is mainly intended for the frequency range 50 Hz to 80 Hz.

NOTE For elements faced with thick, porous absorbers, the recommended frequency range is 50 Hz to 80 Hz.

The main differences between the methods of ISO 15186-1 and ISO 15186-3 are that in ISO 15186-3

  1. the sound pressure level of the source room is measured close to the surface of the test specimen, and

  2. the surface opposite the test specimen in the receiving room is highly absorbing and converts the room acoustically into a duct with several propagating cross-modes above the lowest cut-on frequency.

The results found by the method of ISO 15186-3 can be combined with those of ISO 140-3 and ISO 15186-1 to produce data in the frequency range 50 Hz to 5 000 Hz.

1.2 Precision

The reproducibility of this intensity method is, for all frequencies, estimated to be equal to or better than that found with the method of ISO 140-3 at 100 Hz.

Some comparisons of data obtained with the methods of this part of ISO 15186 and ISO 140-3 are given in annex B.