PRICES include / exclude VAT
Homepage>BS Standards>23 FLUID SYSTEMS AND COMPONENTS FOR GENERAL USE>23.100 Fluid power systems>23.100.40 Piping and couplings>BS ISO 15171-1:1999 Connections for fluid power and general use. Hydraulic couplings for diagnostic purposes Coupling not for connection under pressure
immediate downloadReleased: 1999-10-15
BS ISO 15171-1:1999 Connections for fluid power and general use. Hydraulic couplings for diagnostic purposes Coupling not for connection under pressure

BS ISO 15171-1:1999

Connections for fluid power and general use. Hydraulic couplings for diagnostic purposes Coupling not for connection under pressure

Format
Availability
Price and currency
English Secure PDF
Immediate download
163.80 USD
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
16.38 USD
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
49.14 USD
English Hardcopy
In stock
163.80 USD
Standard number:BS ISO 15171-1:1999
Pages:12
Released:1999-10-15
ISBN:0 580 32980 1
Status:Standard
DESCRIPTION

BS ISO 15171-1:1999


This standard BS ISO 15171-1:1999 Connections for fluid power and general use. Hydraulic couplings for diagnostic purposes is classified in these ICS categories:
  • 23.100.40 Piping and couplings

This part of ISO 15171 specifies dimensions, performance requirements and test procedures for the male quick-action half of a metric coupling with an M14 × 1,5 straight stud end to mate with an ISO 6149-1 port, to be used for diagnostic purposes. Couplings in accordance with this part of ISO 15171 are not designed to connect under pressure. The coupling is designed for use in hydraulic systems that use mineral oil.

NOTE Use of this coupling with fluids other than mineral oil requires agreement between the supplier and the purchaser.

This part of ISO 15171 does not apply to the female half of the mating hydraulic quick-action coupling, which is not on the machine.

Couplings in accordance with this part of ISO 15171 may be used at a maximum working pressure of 40 MPa [400 bar1)]. The permissible working pressure depends upon the materials, design, working conditions, application, etc.

Conformance to the dimensional information in this part of ISO 15171 does not guarantee rated performance. Each manufacturer should perform testing in accordance with the specification contained in this part of ISO 15171 to assure that components comply with the performance rating.