ISO 14001:2026 - Environmental management systems — Requirements with guidance for use - Order now!

PRICES include / exclude VAT
>BSI Standards >13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.040 Air quality>13.040.20 Ambient atmospheres>BS ISO 16000-37:2019 Indoor air Measurement of PM<sub>2,5</sub> mass concentration
immediate downloadReleased: 2019-02-06
BS ISO 16000-37:2019 Indoor air Measurement of PM<sub>2,5</sub> mass concentration

BS ISO 16000-37:2019

Indoor air Measurement of PM<sub>2,5</sub> mass concentration

Format
Availability
Price and currency
English Secure PDF
Immediate download
Printable - You are authorized to print 1 copy
222.64 USD
English Hardcopy
In stock
222.64 USD
Standard number:BS ISO 16000-37:2019
Pages:22
Released:2019-02-06
ISBN:978 0 580 87938 8
Status:Standard
DESCRIPTION

BS ISO 16000-37:2019


This standard BS ISO 16000-37:2019 Indoor air is classified in these ICS categories:
  • 13.040.20 Ambient atmospheres

This document specifies the measurement methods and strategies for determining the PM2,5 mass concentrations of suspended particulate matter (PM) in indoor air. It can also be used for determining PM10 mass concentration.

The reference method principle consists of collecting PM2,5 on a filter after separation of the particles by an impaction head and weighing them by means of a balance.

Measurement procedure and main requirements are similar to the conditions specified in EN 12341.

This document also specifies procedures for operating appropriate supplementary high time resolution instruments, which can be used to highlight peak emission, room investigation and as part of the quality control of the reference method.

Quality assurance, determination of the measurement uncertainty and minimal reporting information are also part of this document.

The lower range of application of this document is 2 µg/m3 of PM2,5 (i.e. the limit of detection of the standard measurement method expressed as its uncertainty).

This document does not cover the determination of bioaerosols or the chemical characterization of particles. For the measurement and assessment of dust composition, see the relevant technical rules in the International Standards in the ISO 16000 series.

This document does not cover passenger compartments of vehicles and public transport systems.


BS ISO 16000-37:2019 Indoor Air Measurement of PM<sub>2.5</sub> Mass Concentration

BS ISO 16000-37:2019 Indoor Air Measurement of PM2.5 Mass Concentration

Ensure the health and safety of indoor environments with the comprehensive standard BS ISO 16000-37:2019, dedicated to the measurement of PM2.5 mass concentration in indoor air. Released on February 6, 2019, this standard is an essential tool for professionals in environmental science, building management, and health and safety sectors.

Overview

With increasing concerns about air quality and its impact on health, the BS ISO 16000-37:2019 standard provides a reliable method for measuring particulate matter (PM2.5) in indoor environments. PM2.5 refers to fine inhalable particles, with diameters that are generally 2.5 micrometers and smaller. These particles can pose significant health risks as they can penetrate deep into the lungs and even enter the bloodstream.

Key Features

  • Standard Number: BS ISO 16000-37:2019
  • Pages: 22
  • Release Date: February 6, 2019
  • ISBN: 978 0 580 87938 8
  • Status: Standard

Why Choose BS ISO 16000-37:2019?

This standard is crucial for anyone involved in the monitoring and management of indoor air quality. It provides a detailed methodology for accurately measuring PM2.5 concentrations, ensuring that environments are safe and compliant with health regulations. By implementing this standard, organizations can:

  • Protect the health of occupants by ensuring air quality is within safe limits.
  • Comply with national and international air quality regulations.
  • Enhance the credibility and reliability of air quality assessments.
  • Identify sources of indoor air pollution and take corrective actions.

Applications

The BS ISO 16000-37:2019 standard is applicable in a variety of settings, including:

  • Residential buildings
  • Commercial and office spaces
  • Healthcare facilities
  • Educational institutions
  • Industrial environments

By utilizing this standard, facility managers, environmental consultants, and health and safety officers can ensure that indoor air quality is monitored and maintained at optimal levels.

Comprehensive Guidance

Spanning 22 pages, the BS ISO 16000-37:2019 standard offers comprehensive guidance on the procedures and equipment necessary for accurate PM2.5 measurement. It covers:

  • Sampling methods and equipment specifications
  • Calibration and maintenance of measurement devices
  • Data analysis and interpretation
  • Reporting and documentation requirements

Enhance Indoor Air Quality Management

Implementing the BS ISO 16000-37:2019 standard is a proactive step towards enhancing indoor air quality management. It empowers organizations to take informed actions based on accurate data, ultimately leading to healthier indoor environments and improved well-being for all occupants.

Conclusion

In a world where air quality is increasingly recognized as a critical component of health and safety, the BS ISO 16000-37:2019 standard stands out as an indispensable resource. By providing a robust framework for measuring PM2.5 mass concentration, it helps organizations meet regulatory requirements and protect the health of individuals in indoor spaces.

Invest in the BS ISO 16000-37:2019 standard today and take a significant step towards ensuring cleaner, safer indoor air for everyone.