PRICES include / exclude VAT
Homepage>BS Standards>27 ENERGY AND HEAT TRANSFER ENGINEERING>27.020 Internal combustion engines>BS ISO 4548-12:2017 Methods of test for full-flow lubricating oil filters for internal combustion engines Filtration efficiency using particle counting and contaminant retention capacity
Sponsored link
immediate downloadReleased: 2017-07-11
BS ISO 4548-12:2017 Methods of test for full-flow lubricating oil filters for internal combustion engines Filtration efficiency using particle counting and contaminant retention capacity

BS ISO 4548-12:2017

Methods of test for full-flow lubricating oil filters for internal combustion engines Filtration efficiency using particle counting and contaminant retention capacity

Format
Availability
Price and currency
English Secure PDF
Immediate download
317.20 USD
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
31.72 USD
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
95.16 USD
English Hardcopy
In stock
317.20 USD
Standard number:BS ISO 4548-12:2017
Pages:44
Released:2017-07-11
ISBN:978 0 580 88924 0
Status:Standard
DESCRIPTION

BS ISO 4548-12:2017


This standard BS ISO 4548-12:2017 Methods of test for full-flow lubricating oil filters for internal combustion engines is classified in these ICS categories:
  • 27.020 Internal combustion engines

This document specifies a multi-pass filtration test with continuous contaminant injection and using the online particle counting method for evaluating the performance of full-flow lubricating oil filters for internal combustion engines. The scope of this document is limited to steady state conditions and does not address fluctuations in the flow rate.

The test procedure determines the contaminant capacity of a filter, its particulate removal characteristics and differential pressure.

This test is intended for application to filter elements with an efficiency of less than 99 % at particle size greater than 10 μm.

NOTE Several test flow loops built into one test rig, or several test rigs, would be necessary to cover the complete flow range of 2 l/min to 600 l/min.