ISO 14001:2026 - Environmental management systems — Requirements with guidance for use - Order now!

PRICES include / exclude VAT
>CSN Standards>69 MACHINERY FOR CHEMICAL INDUSTRY>6982 Steel reservoirs>CSN EN 12285-4 - Workshop fabricated steel tanks - Part 4: Vertical cylindrical single skin and double skin tanks for the aboveground storage of flammable and nonflammable water polluting liquids other than for heating and cooling of buildings
Released: 01.05.2026
CSN EN 12285-4 - Workshop fabricated steel tanks - Part 4: Vertical cylindrical single skin and double skin tanks for the aboveground storage of flammable and nonflammable water polluting liquids other than for heating and cooling of buildings

CSN EN 12285-4

Workshop fabricated steel tanks - Part 4: Vertical cylindrical single skin and double skin tanks for the aboveground storage of flammable and nonflammable water polluting liquids other than for heating and cooling of buildings

Format
Availability
Price and currency
English Hardcopy
In stock
129.41 USD
FREE Shipping
Number of Standard:CSN EN 12285-4
Category:698235
Pages:40
Released:01.05.2026
Catalog number:523307
DESCRIPTION

CSN EN 12285-4

CSN EN 12285-4 This document specifies the requirements for metallic shop fabricated shop fabricated cylindrical vertical steel tanks, single and double skin for the aboveground storage of water polluting liquids (both flammable and non-flammable) within the following limits: - from 1250 mm up to 4 000 mm inner tank nominal diameter and, - up to maximum overall length of 6 times the nominal inner tank diameter and - tank possible to be divided from 1 to 5 compartments - for liquids with maximum density of up to 1,9 kg/l and, - with an operating pressure (P0) of maximum 50kPa (0,5 bar (g)) and minimum - 5 kPa (- 50 mbar (g)) and, - where double skin tanks with vacuum leak detection system are used, the cinematic viscosity of the stored media does not exceed 5 x 10-3 m2/s This document is applicable for normal ambient temperature conditions (-40 °C to + 50 °C). Where temperatures are outside this range, additional requirements are taken into account. This document is not applicable to tanks used for storage and/or supply of fuel/gas for building heating/cooling systems, and of hot or cold water not intended for human consumption, nor to loads and special measures necessary in areas subject to risk of earthquakes. This document is not applicable for the storage of liquids having dangerous goods classes listed in Table 1 because of the special dangers involved. Table 1 - List of dangerous goods which are not covered by this standard UN-classification Type of dangerous goods Class 1 Explosives Class 4.2 Substances liable to spontaneous combustion Class 4.3 Substances which in contact with water emit flammable gases Class 5.2 Organic peroxides Class 6.2 Infectious substances Class 7 Radioactive substances, hydrocyanic or hydrocyanic solvent liquids, metal carbons, hydrofluoric acid, bromide liquids OTE - The classifications referred to are those adopted by the United Nations Committee of Experts on the Transport of Dangerous Goods (not to be interpreted as tank classes described in 6.2).
Original English text of CSN EN Standard.
The price of the Standard included all amendments and correcturs.