PRICES include / exclude VAT
Homepage>CSN Standards>25 MEASURING INSTRUMENTS>2577 Measuring of liquids and gases flow through throttling elements>CSN EN ISO 5167-3 - Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 3: Nozzles and Venturi nozzles
Released: 01.04.2023
CSN EN ISO 5167-3 - Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 3: Nozzles and Venturi nozzles

CSN EN ISO 5167-3

Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 3: Nozzles and Venturi nozzles

Format
Availability
Price and currency
English Hardcopy
In stock
102.22 USD
FREE Shipping
Number of Standard:CSN EN ISO 5167-3
Category:257710
Pages:56
Released:01.04.2023
Catalog number:516581
DESCRIPTION

CSN EN ISO 5167-3

CSN EN ISO 5167-3 This document specifies the geometry and method of use (installation and operating conditions) of nozzles and Venturi nozzles when they are inserted in a conduit running full to determine the flowrate of the fluid flowing in the conduit. This document also provides background information for calculating the flowrate and is applicable in conjunction with the requirements given in ISO 5167-1. This document is applicable to nozzles and Venturi nozzles in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. In addition, each of the devices can only be used within specified limits of pipe size and Reynolds number. It is not applicable to the measurement of pulsating flow. It does not cover the use of nozzles and Venturi nozzles in pipe sizes less than 50 mm or more than 630 mm, or where the pipe Reynolds numbers are below 10 000. This document deals with a) three types of standard nozzles: 1) ISA 19321) nozzle; 2) the long radius nozzle2); 3) the throat-tapped nozzle b) the Venturi nozzle. The three types of standard nozzle are fundamentally different and are described separately in this document. The Venturi nozzle has the same upstream face as the ISA 1932 nozzle, but has a divergent section and, therefore, a different location for the downstream pressure tappings, and is described separately. This design has a lower pressure loss than a similar nozzle. For all of these nozzles and for the Venturi nozzle direct calibration experiments have been made, sufficient in number, spread and quality to enable coherent systems of application to be based on their results and coefficients to be given with certain predictable limits of uncertainty.
Original English text of CSN EN Standard.
The price of the Standard included all amendments and correcturs.