PRICES include / exclude VAT
Homepage>IEC Standards>IEC 60076-11:2018 - Power transformers - Part 11: Dry-type transformers
Sponsored link
download between 0-24 hoursReleased: 2018-08-15
IEC 60076-11:2018 - Power transformers - Part 11: Dry-type transformers

IEC 60076-11:2018

Power transformers - Part 11: Dry-type transformers

Transformateurs de puissance - Partie 11 : Transformateurs de type sec

Format
Availability
Price and currency
English/French - Bilingual PDF
Immediate download
421.67 USD
English/French - Bilingual Hardcopy
in stock
421.67 USD
Standard number:IEC 60076-11:2018
Released:2018-08-15
Language:English/French - Bilingual
DESCRIPTION

IEC 60076-11:2018

IEC 60076-11:2018 is now available as IEC 60076-11:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60076-11:2018 applies to dry-type power transformers (including auto-transformers) having values of highest voltage for equipment up to and including 72,5 kV and at least one winding operating at greater than 1,1 kV. This document does not apply to: - gas-filled dry-type transformers where the gas is not air; - single-phase transformers rated at less than 5 kVA; - polyphase transformers rated at less than 15 kVA; - instrument transformers; - starting transformers; - testing transformers; - traction transformers mounted on rolling stock; - flameproof and mining transformers; - welding transformers; - voltage regulating transformers; - small power transformers in which safety is a special consideration. Where IEC standards do not exist for the transformers mentioned above or for other special transformers, this document may be applicable as a whole or in parts. This second edition cancels and replaces the first edition published in 2004 and constitutes a technical revision. The main changes with regard to the previous edition are as follows: - Extension of the scope up to 72,5kV - Enclosure management in regards of the performance - Management of the dielectric and thermal features with altitude - New climatic classes for a better adaptation of customers’ need - Establishment of the relation between location and environmental classes - For fire behaviour classes, limitation at 1000kVA and process of test more robust - Introduction of Seismic class - Recommendations for amorphous transformers Keywords: dry-type transformers The contents of the corrigendum of March 2019 and the Interpretation sheet 1 of July 2020 have been included in this copy.