Released: 12.04.1996

IEEE 115-1995 - IEEE Guide: Test Procedures for Synchronous Machines Part I--Acceptance and Performance Testing Part II-Test Procedures and Parameter Determination for Dynamic Analysis

IEEE Guide: Test Procedures for Synchronous Machines Part I--Acceptance and Performance Testing Part II-Test Procedures and Parameter Determination for Dynamic Analysis

Format
Availability
Price and currency
English PDF
Immediate download
234.36 USD
Standard number:IEEE 115-1995
Released:12.04.1996
ISBN:978-0-7381-0776-9
Pages:198
Status:Active
Language:English
DESCRIPTION

IEEE 115-1995

This guide contains instructions for conducting the more generally applicable and accepted tests to determine the performance characteristics of synchronous machines. Although the tests described are applicable in general to synchronous generators, synchronous motors (larger than fractional horsepower), synchronous condensers, and synchronous frequency changers, the descriptions make reference primarily to synchronous generators and synchronous motors. The tests described may be applied to motors and generators, as needed, and no attempt is made to partition this guide into clauses applying to motors and clauses applying to generators. It is not intended that this guide shall cover all possible tests, or tests of a research nature, but only those more general methods which may be used to obtain performance data. The schedule of factory and field tests which may be required on new equipment is normally specified by applicable standards or by contract specifications. This guide should not be interpreted as requiring the making of any specific test in a given transaction or implying a guarantee to meet specific performance indices or operating conditions. The term specified conditions for tests as used in this guide will be considered as rated conditions unless otherwise agreed upon. Rated conditions apply usually to the following quantities listed on the machine nameplate. These include MVA, terminal voltage (or kilovolts), armature current, and power factor.



Revision Standard - Superseded. Instructions for conducting the more generally applicable and accepted tests to determine the performance characteristics of synchronous machines are contained in this guide. Although the tests described are applicable in general to synchronous generators, synchronous motors (larger than fractional horsepower), synchronous condensers, and synchronous frequency changers, the descriptions make reference primarily to synchronous generators and synchronous motors.