IEEE/ANSI N42.12-1980 - American National Standard Calibration and Usage of Sodium Iodide Detector Systems

American National Standard Calibration and Usage of Sodium Iodide Detector Systems

Format
Availability
Price and currency
English PDF
Immediate download
55.83 USD
Standard number:IEEE/ANSI N42.12-1980
Released:21.11.1980
ISBN:978-0-7381-4163-3
Pages:11
Status:Active
Language:English
DESCRIPTION

IEEE/ANSI N42.12-1980

This standard establishes methods for performance testing, calibration, and usage of sodium iodide detector systems for the measurement of gamma-ray emission rates of radionuclides; the assay for radioactivity; and the determination of gamma-ray energies. It covers both energy calibration and efficiency calibration. The following three techniques are considered: (1) Total spectrum counting (see 5.1) employs a system that counts all events above a low-energy threshold (see 7.1, 7.2, and 7.3). (2) Single-channel analyzer counting (see 5.2) employs a system with a counting window which establishes upper and lower energy boundaries (see 7.1, 7.2, and 7.3). (3) Multichannel analyzer counting (see 5.3) employs a system in which multiple counting windows are utilized. This technique applies to measurements that do not involve overlapping peaks and those for which the continuum under the full-energy peak can be subtracted without introducing unacceptable error [4].

The purpose of this document is to provide a standardized basis for the calibration and usage of sodium iodide detector systems for the measurement of gamma-ray emission rates of radionuclides. Typical applications include radionuclide identification and assay in various industrial, environmental, and medical applications. A sodium iodide detector system consists of: ". . .three major components: a scintillating medium that produces a flash of light when ionizing radiation interacts with it; one or more photomultipliers, optically coupled to the scintillator, which converts the light flash to an amplified electrical impulse; and associated electronic instrumentation which powers the photomultiplier and processes the output signal". [See ANSI/IEEE Std 398-1972 (Reaff 1977), Test Procedures for Photomultipliers for Scintillation Counting and Glossary for Scintillation Counting Field.] The theory of operation of sodium iodide detectors is presented in numerous publications, including refs [1] - [3]

New IEEE Standard - Superseded. Methods are established for performance testing, calibration, and use of sodium iodide detector systems for the measurement of gamma-ray emission rates of radionuclides, assay for radioactivity, and the determination of gamma-ray energies. Both energy calibration and efficiency calibration are covered. Three techniques are considered: total spectrum counting, which employs a system that counts all events above a low-energy threshold; single-channel analyzer counting, which employs a system with a counting window that establishes upper and lower energy boundaries; and multichannel analyzer counting, which employs a system utilizing multiple counting windows.