PRICES include / exclude VAT
Homepage>IEEE Standards>29 ELECTRICAL ENGINEERING>29.130 Switchgear and controlgear>29.130.01 Switchgear and controlgear in general>IEEE C37.24-2003 - IEEE Guide for Evaluating the Effect of Solar Radiation on Outdoor Metal-Enclosed Switchgear
Released: 26.02.2004

IEEE C37.24-2003 - IEEE Guide for Evaluating the Effect of Solar Radiation on Outdoor Metal-Enclosed Switchgear

IEEE Guide for Evaluating the Effect of Solar Radiation on Outdoor Metal-Enclosed Switchgear

Format
Availability
Price and currency
English PDF
Immediate download
141.37 USD
Standard number:IEEE C37.24-2003
Released:26.02.2004
ISBN:978-0-7381-3731-5
Pages:30
Status:Active
Language:English
DESCRIPTION

IEEE C37.24-2003

The general information in this Guide is intended to assist in evaluating the effect of solar radiation on outdoor metal-enclosed switchgear and is applicable to outdoor metal-enclosed power switchgear, control switchboards and metal-enclosed bus. Specific data are given in current temperature relationship and tabulation form for outdoor metal-enclosed low-voltage power circuit breaker switchgear, outdoor metal-clad switchgear and outdoor metal-enclosed interrupter switchgear.

Switchgear will perform satisfactorily and have a reasonable life when operated within the temperature limits estab-lished in ANSI/IEEE C37.20.1, C37.20.2, C37.20.3, C37.21 and C37.23. These standards specify the temperature rise limits above a standard (maximum) ambient temperature of 40 ?C. This is satisfactory for indoor applications where the temperature rise is due entirely to heat release (internal losses). In outdoor applications, the limiting tem-peratures result from the net effect of internal losses and external influences, principally the sun, wind and local am-bient temperatures. All of these must be considered in determining the current-carrying capacity of outdoor metal-enclosed switchgear. The magnitude of these factors will vary geographically and from season to season. The time relationship of maxi-mum circuit loads with respect to maximum ambient temperature is important. It is not practical to design switch-gear on the basis that all adverse factors reach their maxima coincident with maximum loads. If this does not occur, full current ratings may be realized. Recommendations will be made to point out the cumulative effect of these various influences.

Revision Standard - Superseded. This guide provides information to assist in evaluating the effect of solar radiation on outdoor metal-enclosed switchgear including metal-enclosed bus and control switchboards. Specific data are given in the form of a continuous current capability factor for specific maximum monthly normal temperatures at the installation location, to adjust the continuous current capability of outdoor metal-enclosed switchgear to the solar radiation condition required. Tables of maximum monthly normal temperatures at various locations in the US and Canada are provided.