PRICES include / exclude VAT
Homepage>IEEE Standards>29 ELECTRICAL ENGINEERING>29.120 Electrical accessories>29.120.70 Relays>IEEE C37.98-1987 - IEEE Standard Seismic Testing of Relays
Released: 28.12.1987

IEEE C37.98-1987 - IEEE Standard Seismic Testing of Relays

IEEE Standard Seismic Testing of Relays

Format
Availability
Price and currency
English PDF
Immediate download
193.64 USD
Withdraw:18.01.2007
Standard number:IEEE C37.98-1987
Released:28.12.1987
ISBN:978-0-7381-0900-8
Pages:23
Status:Inactive
Language:English
DESCRIPTION

IEEE C37.98-1987



The purpose of this standard is to establish procedures for determining the seismic capabilities of protective and auxiliary relays. These procedures employ what has been called fragility testing in IEEE Std 344-1987. To define the conditions for fragility testing of relays, parameters in three separate areas must be specified. In general, they are: 1) The electrical settings and inputs to the relay, and other information to define its conditions during the test.; 2) The change in state, deviation in operating characteristics or tolerances, or other change of performance of the relay that constitutes failure.; 3) The seismic vibration environment to be imposed during the test. Since it is not possible to define the conditions for every conceivable application for all relays, those parameters, which in practice encompass the majority of applications, have been specified in this standard. When the application of the relay is other than as specified under any of (1), (2), and (3), or if it is not practical to apply existing results of fragility tests to that new application, then proof testing must be performed for that new case. The use of these capability data will assist in the selection of relays. One number will be used to catalog the seismic capability of a relay. This number is the zero period acceleration level, and is understood to refer to the standard response spectrum shape as defined in this standard. The capability data will help designers of generating stations, substations, and various other power system installations to incorporate the seismic capabilities of the relays into the overall design of these facilities.

New IEEE Standard - Inactive-Withdrawn. Administratively Withdrawn January 2007 The procedures to be used in the seismic testing of relays used in power system facilities are specified. The concern is with determining the seismic fragility level of relays. Recommendations for proof testing are given. Documentation and generalization of test results are discussed.