PRICES include / exclude VAT
Homepage>BS Standards>91 CONSTRUCTION MATERIALS AND BUILDING>91.140 Installations in buildings>91.140.90 Lifts. Escalators>BS ISO 8102-2:2021 Electrical requirements for lifts, escalators and moving walks Electromagnetic compatibility with regard to immunity
Sponsored link
immediate downloadReleased: 2021-01-19
BS ISO 8102-2:2021 Electrical requirements for lifts, escalators and moving walks Electromagnetic compatibility with regard to immunity

BS ISO 8102-2:2021

Electrical requirements for lifts, escalators and moving walks Electromagnetic compatibility with regard to immunity

Format
Availability
Price and currency
English Secure PDF
Immediate download
270.40 USD
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
27.04 USD
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
81.12 USD
English Hardcopy
In stock
270.40 USD
Standard number:BS ISO 8102-2:2021
Pages:26
Released:2021-01-19
ISBN:978 0 580 51946 8
Status:Standard
DESCRIPTION

BS ISO 8102-2:2021


This standard BS ISO 8102-2:2021 Electrical requirements for lifts, escalators and moving walks is classified in these ICS categories:
  • 91.140.90 Lifts. Escalators

This document specifies the immunity performance criteria and test levels for apparatus used in lifts, escalators and moving walks which are intended to be permanently installed in buildings including the basic safety requirements in regard to their electromagnetic environment. These levels represent essential EMC requirements.

This document refers to EM conditions as existing in residential, office and industrial buildings.

This document addresses commonly known EMC related hazards and hazardous situations relevant to lifts, escalators and moving walks when they are used as intended and under the conditions foreseen by the lift installer or escalator and/or moving walk manufacturer.

It is assumed that no ports connected to safety circuit only are rated at currents greater than 100 amps.

It is assumed that mobile telephones and radio transmitters used at frequencies and power of that stated in Table 1 are not placed within 200 mm distance from safety circuit(s).

However:

  • performance criteria and test levels for apparatus/assembly of apparatus used in general function circuits do not cover situations with an extremely low probability of occurrence;

  • this document does not apply to other apparatus already proven to be in conformity to the EMC national regulation, and not related to the safety of the lift, escalator or moving walk, such as lighting apparatus, communication apparatus, etc.

This document does not apply to electromagnetic environments such as:

  • radio transmitter stations;

  • railways and metros;

  • heavy industrial plant;

  • electricity power stations;

which need additional investigations.

This document is not applicable to apparatus which were manufactured before the date of its publication.