PRICES include / exclude VAT
Homepage>Sets of EN Standards>Set BS EN 1279-1 to 6 Glass in building - Insulating glass units
Sponsored link
in stockReleased: 2018

Set BS EN 1279-1 to 6 Glass in building - Insulating glass units

Glass in building - Insulating glass units

Format
Availability
Price and currency
English PDF
Immediate download
1712.11 USD
Buy including changes
English Hardcopy
in stock
1712.11 USD
Buy including changes
Released:2018
DESCRIPTION

Set BS EN 1279-1 to 6 Glass in building - Insulating glass units

Saving is € 99 compared to buying individual titles 

 

  • BS EN 1279-1:2018 Glass in building. Insulating glass units Generalities, system description, rules for substitution, tolerances and visual quality
     This document (all parts) covers the requirements for insulating glass units. The main intended uses of the insulating glass units are installations in windows, doors, curtain walling, bonded glazing for doors, windows and curtain walling, roofs and partitions. The achievement of the requirements of this standard indicates that insulating glass units fulfil the needs for intended use and ensures by means of the evaluation of conformity to this standard that, visual, energetic, acoustic, safety parameters do not change significantly over time. In cases where there is no protection against direct ultraviolet radiation or permanent shear load on the edge seal, as in bonded glazing for doors, windows and curtain walling systems, it is essential to follow additional European Technical Specifications (see EN 15434, EN 13022 1 and prEN 16759). Insulating glass units that are intended for artistic purposes (e.g. lead glass or fused glass) are excluded from the scope of this standard. Vacuum insulating glass is not covered by this standard (see ISO DIS 19916 1). Glass/plastics composites are under the scope as long as the surface of contact with sealants is a glass component. NOTE For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply. This European Standard gives definitions for insulating glass units and covers the rules for the system description, the optical and visual quality and the dimensional tolerances thereof and describes the substitution rules based on an existing system description.
  • BS EN 1279-2:2018 Glass in building. Insulating glass units Long term test method and requirements for moisture penetration
    This document describes the test method for the determination of moisture penetration index and specifies the requirements for limit values for insulating glass units made a) in accordance with EN 1279 1:2018 and manufactured to EN 1279 6:2018; or b) for the purpose to demonstrate that components (e.g. edge seals or spacers) will allow the insulating glass unit to conform to the requirements given in EN 1279 1:2018, Clause 6.
  • BS EN 1279-3:2018 Glass in building. Insulating glass units Long term test method and requirements for gas leakage rate and for gas concentration tolerances
    This European Standard describes the test method for the determination of gas leakage rate and specifies the requirements for limit values for gas leakage rate and gas concentration for gas filled insulating glass units made a) in accordance with EN 1279 1:2018 and manufactured to EN 1279 6:2018, or b) for the purpose to demonstrate that components (e.g. edge seals or spacers) will allow the insulating glass unit to conform to the requirements given in EN 1279 1:2018, Clause 6.
  • BS EN 1279-4:2018 Glass in Building. Insulating Glass Units Methods of test for the physical attributes of edge seal components and inserts

  • BS EN 1279-5:2018 Glass in building. Insulating glass units Product standard
    This document covers the product standard of insulating glass units (IGU) for use in buildings. Units for which the intended use is only artistic and therefore no essential characteristics are required, are not subject to CE marking and are not part of this standard. NOTE For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.
  • BS EN 1279-6:2018 Glass in building. Insulating glass units Factory production control and periodic tests
    This document describes the routine factory production control, the periodic testing and inspection and test methods to verify that an insulating glass unit (IGU) conforms to the system description.
Related products
English Secure PDF
Immediate download
317.20 USD
English Hardcopy
In stock
317.20 USD
English Secure PDF
Immediate download
195.00 USD
English Hardcopy
In stock
195.00 USD
English Secure PDF
Immediate download
270.40 USD
English Hardcopy
In stock
270.40 USD
English Secure PDF
Immediate download
377.00 USD
English Hardcopy
In stock
377.00 USD
English Secure PDF
Immediate download
317.20 USD
English Hardcopy
In stock
317.20 USD
English Secure PDF
Immediate download
377.00 USD
English Hardcopy
In stock
377.00 USD