>UNE standards>UNE EN 12101-13:2022 - Smoke and heat control systems - Part 13: Pressure differential systems (PDS) - Design and calculation methods, installation, acceptance testing, routine testing and maintenance
in stockReleased: 2022-11-30
UNE EN 12101-13:2022 - Smoke and heat control systems - Part 13: Pressure differential systems (PDS) - Design and calculation methods, installation, acceptance testing, routine testing and maintenance

UNE EN 12101-13:2022

Smoke and heat control systems - Part 13: Pressure differential systems (PDS) - Design and calculation methods, installation, acceptance testing, routine testing and maintenance

Sistemas para el control de humo y de calor. Parte 13: Sistemas de presión diferencial (PDS). Métodos de diseño y cálculo, instalación, ensayos de aceptación, pruebas rutinarias y mantenimiento.

Format
Availability
Price and currency
English PDF
Immediate download
Printable
198.00 USD
English Hardcopy
In stock
198.00 USD
Spanish PDF
Immediate download
Printable
198.00 USD
Spanish Hardcopy
In stock
198.00 USD
Standard number:UNE EN 12101-13:2022
Pages:121
Released:2022-11-30
Status:Standard
Pages (Spanish):131
DESCRIPTION

UNE EN 12101-13:2022

This document gives guidance and requirements for the design and calculation methods, installation, acceptance testing, routine testing and maintenance for pressure differential systems (PDS). PDSs are designed to hold back smoke at a leaky physical barrier in a building, such as a door (either open or closed) or other similarly restricted openings and to keep tenable conditions in escape and access routes depending on the application. It covers systems intended to protect means of escape e.g. staircases, corridors, lobbies, as well as systems intended to provide a protected firefighting bridgehead for the fire services. It provides details on the critical features and relevant procedures for the installation. It describes the commissioning procedures and acceptance testing criteria required to confirm that the calculated design is achieved in the building. This document gives complete rules, requirements and procedures to design PDS for buildings up to 60 m. For buildings taller than 60 m the same requirements are given (e.g. Table 1), but additional calculations and verification methods are necessary. Requirements for such methods and verification are given in Annex D, but the methods fall outside the scope of this document [e.g. Computational Fluid Dynamics (CFD)]. Routine testing and maintenance requirements are also defined in the document. In the absence of national requirements and under expected ambient and outside conditions, the requirements in Table 1 are fulfilled by the PDS.