>UNE standards>UNE EN IEC 60601-2-21:2021 - Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers (Endorsed by Asociación Española de Normalización in September of 2021.)
in stockReleased: 2021-09-01
UNE EN IEC 60601-2-21:2021 - Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers (Endorsed by Asociación Española de Normalización in September of 2021.)

UNE EN IEC 60601-2-21:2021

Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers (Endorsed by Asociación Española de Normalización in September of 2021.)

Equipos electromédicos. Parte 2-21: Requisitos generales para la seguridad básica y funcionamiento esencial de las incubadoras radiantes para recién nacidos. (Ratificada por la Asociación Española de Normalización en septiembre de 2021.)

Format
Availability
Price and currency
English PDF
Immediate download
Printable
120.35 USD
English Hardcopy
In stock
120.35 USD
Standard number:UNE EN IEC 60601-2-21:2021
Pages:46
Released:2021-09-01
Status:Standard
DESCRIPTION

UNE EN IEC 60601-2-21:2021

201.1 Scope, object and related standards Clause 1 of the general standard1) applies, except as follows: 201.1.1 Scope Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT RADIANT WARMERS as defined in 201.3.204, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE See also 4.2 of the general standard. This particular standard specifies the safety requirements for INFANT RADIANT WARMERS, but alternate methods of compliance with a specific clause, by demonstrating equivalent safety, will not be judged as non-compliant, if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device. This particular standard does not apply to: devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use; for information see IEC 80601-2-35; INFANT INCUBATORS; for information see IEC 60601-2-19; INFANT TRANSPORT INCUBATORS, for information see IEC 60601-2-20; INFANT PHOTOTHERAPY EQUIPMENT, for information see IEC 60601-2-50. 201.1.2 Object Replacement: The object of this particular standard is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for INFANT RADIANT WARMERS as defined in 201.3.204, which minimize HAZARDS to PATIENT and OPERATOR, and to specify tests by which compliance with the requirements can be verified.